MaxAttach NAS 6000 Administration Guide
A hard disk failed because device is not ready. (46, 46, 1, Serious)
n
A hard disk failed because device was not found on start up. (47, 47, 1, Serious)
n
A hard disk failed because write operation of the 'Configuration On Disk' failed. (48,
n
48, 1, Serious)
A hard disk failed because write operation of 'Bad Data Table' failed. (49, 49, 1,
n
Serious)
Physical device status changed to offline. (50, 50, 3, Warning)
n
Physical device failed to start. (54, 54, 3, Warning)
n
Physical drive missing on startup. (57, 57, 1, Serious)
n
Viewing and Changing Error Codes
You can view Error Codes individually, and change Error Codes using the Event Editor.
To change an error code description
1.
Select Administration > Settings and then select the Event Editor Tab.
2.
In the Event ID Field, select the event number.
3.
In the User Event ID Field, enter the ID number.
4.
In the Severity Field, select the severity level.
5.
Use the check boxes to configure your error event at to:
Alarm Sound
n
Pager Notification
n
Email Notification
n
Fax Notification
n
Launch Application.
n
6.
If required, in the Event Message Text Field, edit the message.
7.
If you make a mistake, click on the Default All button to reset the message to the
default settings.
8.
To commit your changes, click on the OK button.
Chapter #14 - Appendix - Disk Array Error Codes
11/07/01 -- Revision 2.0.03A
Chapter #14 - Appendix - Disk Array Error Codes
Viewing and Changing Error Codes
282
000001628