MaxAttach NAS 6000 Administration Guide
Table #2 - Disk Array Components by SCSI Bus & ID Number (Sheet 2 of 2)
SCSI
Component Name
Bus:ID
1-13
Hard Disk Drive
1-14
Hard Disk Drive
1-15
Hard Disk Drive
2-0
Hard Disk Drive
2-1
Hard Disk Drive
2-2
Hard Disk Drive
2-3
Hard Disk Drive
2-4 to 2-6
Not Used
2-7
SCSI Controller Card - Channel 2
2-8 to 2-15
Not Used
3-0 to 3-3
Not Used
3-4
Channel-3 SCSI Bridge Board
3-5 & 3-6
Not Used
3-7
SCSI Controller Card - Channel 3
3-8
Hard Disk Drive
3-9
Hard Disk Drive
3-10
Hard Disk Drive
3-11
Hard Disk Drive
3-12
Hard Disk Drive
3-13
Hard Disk Drive
3-14
Hard Disk Drive
3-15
Hard Disk Drive

RAID Array Organization

The system logical drives are default configured as Redundant Arrays of Independent Disks
(RAID). the RAID methodology and technique used varies with the function of the
logical drive. The RAID techniques used in each logical drive are:
Base Unit Drive C:\ - System O/S:
Factory configured
n
A first RAID 1 striped across a partition on three drives with a second RAID 1 striped
n
across another partition on three different drives.
The two RAID 1 arrays above are combined into a RAID 0 mirrored array.
n
This array cannot be changed without damaging the O/S image.
n
Chapter #4 - Overview - NAS 6000 Disk Array
11/07/01 -- Revision 2.0.03A
Component Location - Drive Number from
Second Expansion Unit, Drive 3
Second Expansion Unit, Drive 2
Second Expansion Unit, Drive 1
Base Unit, Drive 12
Base Unit, Drive 11
Base Unit, Drive 10
Base Unit, Drive 9
Mylex SCSI RAID Controller is located in the Base Unit card cage. ID 2-7
controls all devices on Bus 2.
Base and Expansion Units. ID shared by all Channel 3 Bridge Boards.
One Channel 3 Bridge board is located on each Expansion Unit. There is
no Channel 3 Bridge board in the Base Unit.
Base Unit - Mylex SCSI RAID Controller is located in the Base Unit card
cage. ID 3-7 controls all devices on Bus 3.
First Expansion Unit, Drive 12
First Expansion Unit, Drive 11
First Expansion Unit, Drive 10
First Expansion Unit, Drive 9
Second Expansion Unit, Drive 12
Second Expansion Unit, Drive 11
Second Expansion Unit, Drive 10
Second Expansion Unit, Drive 9
122
Chapter #4 - Overview - NAS 6000 Disk Array
RAID Array Organization