MaxAttach NAS 6000 Administration Guide
MaxAttach SNMP Traps
The MaxAttach supports all of the standard Microsoft Windows 2000 events, and a
number of these events pertinent to the functioning of the MaxAttach are sent as SNMP
traps. The following event categories are supported as SNMP traps:
Disk Events (ATAPI, Disk, DiskPerf, Dmboot, Dmio, LDM)
n
Power (UPS)
n
In addition, the MaxAttach also provides traps for its internal environmental monitoring
unit (EMU).
Trap
Trap
Power Supply Status
Fan Status
Disk Drive Present Status
Temperature Status
Disk Backplane Voltage Status
Intrusion Status
Chapter #12 - Appendix - SNMP
11/07/01 -- Revision 2.0.03A
Table #1 - Environmental Monitoring Unit Traps
Event ID
Event ID
2110 Information
2310 Error
2120 Information
2320 Error
2130 Information
2330 Error
2150 Information
2350 Error
2160 Information
2360 Error
2180 Information
2380 Error
Description
Present, Over temp, AC fail, DC fail
Fan running, Fan Stalled
Present, Not Present
Temperature Levels 1, 2, or 3, where 3 is hottest
Voltages Nominal (+/- 5%), Out of tolerance
Intrusion Detected
276
Chapter #12 - Appendix - SNMP
MIB Specifications
Description
000001628