Setting up Extensions

Setting the Line Properties

For a physical extension, you can configure hardware options on the board
port used for the extensions. To do so, select the extension number in the
list of extensions, then click the Line Properties button to open a dialog
box that is specific to the board using for the extension.
The Line Properties are somewhat different for Quantum Board than for
Triton Analog Station Boards. The subsequent sections deal first with
Quantum, then with Triton Analog Extension.
Quantum Line Properties
If you select a Quantum board extension and click Line Properties, you'll
see the Quantum Line Properties dialog box. Note that you can use the
Apply to button to apply these hardware settings to one, some, or all ports
on the board.
Figure 7. Quantum Line Properties dialog box for extensions
Configure the following hardware extension-specific features:
Parameter
Message Waiting
Signal Type
10-16 AltiWare OE System Installation & Administration Manual
Description
Type of Message Waiting indicator for the phone set:
• None.
• Voltage—voltage-based indicator.
• FSK—Frequency Shift Keying indicator.
• Tone—tone-based indicator.