Parameter
Flash Duration
Ringing Frequency
Line Disconnect
Signal
Ringing Frequency
Caller ID
Transmission
Methods
Receiver Gain/
Transmission
Attenuation
Caution: If the Receiver Gain or the Transmission Attenuation
setting is too high, the result will be distortion in voice
quality.

Feature Profile

Use the Feature Profile drop-down list to select an extension feature
profile that includes enabling or disabling of extension features. The
feature profile must first be configured by the administrator in the Feature
Profiles page of System Configuration ("Feature Profiles" on page 5-39).
AltiWare OE System Installation & Administration Manual
Extension and Group Configuration
Description
Specifies the Flash Duration time in milliseconds:
50-600
100-700
150-800
200-900
300-1000
Specifies the number of rings: 28 or 20
The loop break desired for answering supervision,
either 200 or 600 ms.
Select the frequency in Hz that is necessary for the
equipment attached to this line.
Specifies how Caller ID will be detected:
CID between 1st and 2nd ring - Caller ID is
received between first and second ring.
DT-AS+CID prior to ringing - Dual Tone
Alerting Signal Caller ID is received prior to
ringing.
RP-AS+CID prior to ringing - Ring Pulse
Alerting Signal Caller ID is received prior to
ringing.
Incoming and outgoing volume for every extension.
Unlike the Quantum board, these slide settings have
positive and negative values. Both defaults are 0
decibels. The range is -3 to +3 decibels.