MVIP Clock Configuration

MVIP Clock Configuration
Figure 2. MVIP Configuration Dialog Box
The Clock Configuration dialog box (see Figure 2) allows the system
administrator to automatically run the MVIP test tool at start up, and to
automatically or manually choose the master board.
If the Automatically run MVIP test tool at startup option is checked,
you can further enable testing of the following options—Connection
Memory, Connection Register, Data Memory and Cross Talk.
By default, the setting of the clock configuration is set to Auto. This means
that the system automatically checks all the boards for the most stable clock
and designates that board as the master reference clock by which all other
boards reference their clocks.
Note:
It is recommended to use the Auto setting. Do not select Manual
unless one of your digital spans is connected to equipment other
than the PSTN (your regular phone network). It is also
recommended that you select the Auto setting if there is only one
T1/PRI board present in the system.
You can select Manual to choose the board to serve as the master clock for
the other boards in the system. Click on the arrow to scroll down through
the list of boards. It is recommended that you select the Manual setting
when there are two or more T1/PRI boards present in the system.
16-4 AltiWare OE System Installation & Administration Manual