Service Parameters For T1 - Altigen AltiWare OE/ACC Version 5.0A Administration Manual

Table of Contents

Advertisement

Important: Configuration for Triton T1/E1/PRI boards can only be done at
the local system. These boards cannot be configured by a
remote AltiAdmin.

Service Parameters for T1

To subscribe to T1 service, certain parameters are required to establish
service. The information provided below identifies the recommended and
supported parameters for T1 service.
T1 Service Request Information
When ordering T1 service, provide the following service request
information:
Equipment Information
Product Manufacturer - AltiGen Communications, Inc.
Product Name - AltiServ PBX Phone System
CSU/DSU - ADTRAN T1 ACE (recommended) or other CSU/DSU
Technical Information for T1 with Voice
Signaling Protocol:
• E&M Wink Start (recommended)
• E&M Immediate Start
• Ground Start
• Loop Start (not recommended)
Trunk Type:
• DID
• 2-Way DID (recommended)
• DOD
Framing:
• Super Frame (SF)/D4
• Extended Super Frame (ESF) (recommended)
Line Coding:
• Alternate Mark Inversion (AMI)