Table 115 System Error Logs - ZyXEL Communications ZYWALL P1 User Manual

Internet security appliance
Hide thumbs Also See for ZYWALL P1:
Table of Contents

Advertisement

Chapter 22 Logs
Table 114 System Maintenance Logs (continued)
LOG MESSAGE
Connect to Daytime server
fail
Connect to Time server fail
Connect to NTP server fail
Too large ICMP packet has
been dropped
Configuration Change: PC =
0x%x, Task ID = 0x%x
Successful SSH login
SSH login failed
Successful HTTPS login
HTTPS login failed
DNS server %s was not
responding to last 32
consecutive queries...
DDNS update IP:%s (host %d)
successfully
SMTP successfully
myZyXEL.com registration
successful
Trial service registration
successful
Service upgrade successful
Service refresh successful.
IDP/Anti-Virus trial service
activation successfully
%s

Table 115 System Error Logs

LOG MESSAGE
%s exceeds the max.
number of session per
host!
setNetBIOSFilter: calloc
error
readNetBIOSFilter: calloc
error
WAN connection is down.
348
DESCRIPTION
The router was not able to connect to the Daytime server.
The router was not able to connect to the Time server.
The router was not able to connect to the NTP server.
The router dropped an ICMP packet that was too large.
The router is saving configuration changes.
Someone has logged on to the router's SSH server.
Someone has failed to log on to the router's SSH server.
Someone has logged on to the router's web configurator
interface using HTTPS protocol.
Someone has failed to log on to the router's web configurator
interface using HTTPS protocol.
The specified DNS server did not respond to the last 32
consecutive queries.
The device updated the IP address of the specified DDNS
host name.
The device sent an e-mail.
Registration of the device with myZyXEL.com was
successful.
Registration for a trial service was successful.
Registration for a service upgrade was successful.
The device successfully refreshed service information from
myZyXEL.com.
The IDP and anti-virus trial service was successfully activated
for this device.
The myZyXEL.com service registration failed due to the error
listed. If you are unable to register for services at
myZYXEL.com, the error message displayed in this log may
be useful when contacting customer support.
DESCRIPTION
This attempt to create a NAT session exceeds the maximum
number of NAT session table entries allowed to be created per
host.
The router failed to allocate memory for the NetBIOS filter
settings.
The router failed to allocate memory for the NetBIOS filter
settings.
A WAN connection is down. You cannot access the network
through this interface.
ZyWALL P1 User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents