Omron NT - SUPPORT TOOL 07-1995 Operation Manual page 83

Table of Contents

Advertisement

Common Setting Operations
64
S Ref Table
Specify the number of the numeral table to be referenced here.
Pressing the [F1] key enables selection from a numeral table list.
S Integer:
Specify the number of digits in the integral part of the numeric
value here.
S Decimal:
Specify the number of digits in the decimal fraction here.
S Disp Type:
Specify whether the displayed numeric value will be decimal or
hexadecimal format.
When using an NT20S, NT20M, NT600S, or NT600M and not
using direct connection, only decimal values can be displayed
and this setting is therefore ineffective.
S Zero Sup:
When "No" is specified here, if the numeric value does not have
the available number of digits, "0" will be displayed for the digits
preceding the digits comprising the numeric value.
S Disp Sign:
When "Yes" is specified here, a minus sign will be displayed for
negative numeric values (when using direct connection, these
are decimal format numbers with "F" at the head).
S Size:
Three fonts are available for numeric value display: "Half",
"Norm" and "Wide".
Half-size
S Scale:
Characters can be displayed at magnifications from 1x (Equ) to
64x.
However, note that 64x cannot be specified with an NT20S or
NT20M.
S Attribute:
Numeric values can be displayed with any of the following
attributes: "Norm" (normal), "Inv." (inverted), "Flsh" (flashing),
or "Spot". For screen data of models other than the NT30C and
NT610C, "Flsh" and "Spot" are displayed in yellow on the
support tool screen.
S Smoothing:
This function smooths out the jagged appearance of magnified
numerals. It can be specified for numerals whose scale is 4x or
greater.
With the NT20S, NT20M, NT600S, and NT600M, smoothing is
always performed on characters and marks with a magnifica-
tion of 4 or greater and this setting is therefore not used.
Normal
Wide
Section 4-2