Common Setting Operations
Reference: If the host interface unit's DIP switch is set for initialization of the data contents of
Procedure 1. Locate the bar cursor at the number of the character-string memory table to be
Reference: S Data can be copied into the next character-string memory table by pressing [F2]
S In:
Execution/non-execution of character-string table
initialization in accordance with initial values set using the
support tool when the PT is started up.
S #:
Number of words used at the PC for reference by the
character-string memory table.
S Word:
First word (lower word) in the data area at the PC
referenced by the character-string memory table.
The entry in the parentheses to the right is a comment input
when word setting was performed. It gives information such
as the contents of the word.
the allocated words in the PC, the "Initial Value" setting will be invalidated.
<Setting method>
set.
[Shift] + [ ] or [Shift] + [ ] can be used to move the bar cursor to the previous or
"
next character-string memory table for which the "Initial Data" setting is not
blank.
Press the [Tab] key to display the memory table number input field.
"
Press the [F1] (Ref) key to display the screen number that references the char-
"
acter-string memory table in question.
Press [F5] (Srch) to search for initial values or allocated words. See "Search-
"
ing within a Memory Table" (p.78).
(iCopy). Incrementing processing is performed in accordance with the setting
made with [F3] (iCopySet). See "Copying to the Next Input Field (Increment
Copy)" (p.77).
S Allocated bits of a character-string memory table can be changed in a batch with
a designated range by pressing [F4] (Btch Chng). See "Batch Changing Bits and
Words" (p.79).
2. Press the
key in the "Init Val" input field, input the initial value of the charac-
ter-string memory table, then press the
Input character-strings can be deleted by pressing the [Home] key.
3. If using direct connection, to initialize the character-string memory table when
it is started, move the bar cursor to the "In" input field and press the [SPACE]
(Init) key.
4. If using direct connection, press the
ber of words (1 to 20), then press the
5. If using direct connection, carry out word setting.
For details of the setting procedure, see "Setting Words and Bits" (p.75).
Section 4-2
key again.
key in the "#" input field, input the num-
key again.
71