Omron NT - SUPPORT TOOL 07-1995 Operation Manual page 133

Table of Contents

Advertisement

Setting Touch Switches
114
S No. /Lamp Bit:
If not using direct connection, set the touch switch number. If
using direct connection, set the PC bit that controls the ON,
OFF, or flashing state of the touch switch (lamp bit).
S Label:
Set the characters (label) that will be displayed together with
the touch switch. If this setting is omitted, nothing will be dis-
played together with the touch switch.
S Pressing the [F3] (Mark) key allows marks to be input.
S With the NT30, NT30C, NT612G, and NT610C, pressing
[F4] (Image) allows images to be input.
S Details
S Inverse:
Specifies whether the graphic will be inverted when there is
input on the PT screen.
[Normal, solid 1, square, circle, polygon, fan]
Other than NT30C and NT610C:
NT30C, NT610C:
[Solid 2] (NT30, NT30C, NT610C only)
S Attribute: Specify ON display or flashing display.
When using an NT20S, NT20M, NT600S, or NT600M, the
setting is fixed as "ON display" and cannot be specified.
S Shape:
Specifies the type of touch switch display area.
S Color:
Specifies the frame color, OFF color, ON color (inverted color
when ON) and flashing color (NT30C, NT610C only).
S Label Det:
Set the label display settings.
Display attributes and smoothing cannot be specified with the
NT20S, NT20M, NT600S, or NT600M. It is also not possible to
specify a scale of x64 when using an NT20S or NT20M.
S Label Col:
Specifies the character color and background color of the "Label"
(NT30C, NT610C only).
4. Press the
key with the cursor on "Exec".
5. If "square", "circle", "polygon", or "fan" was specified for the shape of the dis-
play area, create the graphic.
For details on how to create the graphic, see 4-3 "Creating Fixed Displays"
(p.80).
Section 4-7
Becomes inverted
Assumes the ON color
Input
inversion