Functions
14.4 PROFINET communication
14.4
PROFINET communication
14.4.1
PROFINET IO fieldbus
Overview
You can integrate the converter into a PROFINET network.
Description of function
Figure 14-4
The converter supports the following functions:
• RT (Real-Time)
• IRT (Isochronous Real-Time)
• MRP (Media Redundancy Protocol): Media redundancy, with transition bump
• MRPD (Media Redundancy Planned Duplication): Media redundancy, bumpless.
• Shared device: two different controls access the converter in parallel and independently
• System redundancy S2
• Diagnostic alarms in accordance with the error classes specified in the PROFIdrive profile.
• Device replacement without removable data storage medium: The replacement converter is
assigned the device name from the IO controller, not from its memory card or from the
programming device.
14.4.2
Configuring PROFINET IO operation
14.4.2.1
Connecting the PROFINET cable to the converter
Requirement
You have set up a PROFINET network for connecting the converter.
326
The converter in PROFINET IO operation (examples)
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB