Safe Stop 1 With Braking Ramp Monitoring (Ss1-R) - Siemens SINAMICS G220 Operating Instructions Manual

Table of Contents

Advertisement

Functions
14.12 Safety Integrated
Number
p9548
p9548
p9556
p9560
p9560
p9568
p9568
p9582
p9603.0...1
p9604.0...30
p9606
r9714[0...4]
r9714[0...4]
r9720.0...15
r9722.0...15
c10023
r10353.0...17
14.12.4.5

Safe Stop 1 with braking ramp monitoring (SS1-r)

Overview
With SS1-r, while braking, the converter monitors whether the speed of the motor remains
below a defined ramp using the safe brake ramp monitoring (SBR).
666
Name
SI SAM velocity tolerance
SI SAM velocity tolerance
SI transition time SS1 to STO
SI STO shutdown velocity
SI STO shutdown velocity
SI SAM velocity limit
SI SAM velocity limit
SI SAM/SBR delay time
SI control
SI enable
SI SS1 function specification
SI diagnostics velocity
SI diagnostics velocity
SI control word
SI status signals
SI SS1 input terminal
SI SS1 select cause
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
Unit
[mm/min]
[rpm]
[ms]
[mm/min]
[rpm]
[mm/min]
[rpm]
[ms]
 
 
 
[mm/min]
[rpm]
 
 
 
 
SINAMICS G220 converter

Advertisement

Table of Contents
loading

Table of Contents