Device configuration and basic parameterization

11.3.1

Overview

Note
Only in the offline mode 
The drive components can only be combined and specified in the offline mode. In the online
mode, all corresponding setting ranges are marked in the device view and in the inspector
window.
Note
User management and security
SINAMICS drives of the latest generation generally have extended protection. This usually has
the effect that, as a user, you have to log in to view or edit the drive data offline as well as online.
The most important protective measures in brief:
• Project protection can be activated for Startdrive projects in the TIA Portal (offline). If project
protection is activated, corresponding rights are required for access. Once project protection
has been activated, it cannot be deactivated.
• A "Security Wizard" usually appears when creating new drives in the project. The Security
Wizard helps you to make the most important security settings for this drive in the project
when creating the drive. After loading the project data into the drive, the protection settings
become effective in the drive.
• To access a protected drive online, you need the corresponding access rights. This also
applies if no project protection is activated for the Startdrive project.
Detailed information on this topic can be found under "User management and security
(Page 291)".
Note
Editing mode required for online commissioning
If you want to make important settings online, activation of the editing mode is mandatory.
Restore points that are required as a return point following a cancellation of the current online
parameterization are automatically created by the editing mode in the "guided quick startup"
(and in the "Parameterization" area) during configuration.
No separate editing mode is necessary in the "Rotate & optimize" area.
Note
Telegram configuration offline
In the guided quick startup, telegram settings can in principle only be made offline.
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB
11.3 Device configuration and basic parameterization
Commissioning (Startdrive)
283