12.2

Operation Mode Shift at Power-On

The FPGA module enters one of the following operation modes when the power is turned on.
• CC-Link IE TSN communication mode
• CC-Link IE TSN synchronous communication mode
• Standalone mode
• Standalone mode (IP address initialization)
• Unit test mode
CC-Link IE TSN communication mode
The module operates as a remote station for CC-Link IE TSN communication in this mode.
The module switches to CC-Link IE TSN communication mode if any of the following conditions are met.
• The function setting switch 1 is set to OFF, and "Network Synchronous Communication" is set to "Asynchronous".
• The function setting switch 1 is set to OFF, and the module is connected to the master station whose inter-module
synchronous communication is not set with this module.
CC-Link IE TSN synchronous communication mode
The module operates as a remote station for CC-Link IE TSN communication in synchronization with the synchronization
cycle of the master station in this mode.
If all of the following conditions are met, the CC-Link IE TSN synchronous communication mode is entered.
• Function setting switch 1 is OFF.
• Function setting switch 2 is OFF.
• "Network Synchronous Communication" is set to "Synchronous".
• The module is connected to the master station whose inter-module synchronous communication is set with this module.
Standalone mode
The module operates independently according to the parameters set by the FPGA module configuration tool and operates
according to SLMP commands sent from SLMP compatible devices.
If all of the following conditions are met, it will switch to standalone mode.
• Function setting switch 1 is ON.
• Function setting switch 2 is OFF.
Standalone mode (IP address initialization)
This mode is for initializing the IP address and subnet mask saved in the non-volatile memory of the FPGA module.
If all of the following conditions are met, the module switches to standalone mode (IP address initialization).
• IP address/station number setting switch (x1): F
• IP address/station number setting switch (x16): F
• Function setting switch 1 is ON.
• Function setting switch 2 is ON.
Unit test mode
This mode checks if there is an abnormality in the hardware of the FPGA module.
If all the following conditions are met, the unit test mode is entered.
• IP address/station number setting switch: other than 255
• Function setting switch 1 is ON.
• Function setting switch 2 is ON.
12 FUNCTIONS