Chapter 14 Sample Circuit In Cc-Link Ie Tsn Communication Mode - Mitsubishi Electric NZ2GN2S-D41P01 User Manual

Cc-link ie tsn fpga module
Table of Contents

Advertisement

14
SAMPLE CIRCUIT IN CC-LINK IE TSN
COMMUNICATION MODE
This chapter describes how to use the following functions of the sample circuit when setting the CC-Link IE TSN
communication mode. Refer to the section for a desired function to be set.
• Inversion output function of the digital control part ( Page 402 When Using the Inversion Output Function)
• Pulse count function of the counter control part ( Page 405 When Using the Pulse Count Function)
• Output block part A/D conversion function ( Page 408 When Using the A/D Conversion Function)
• D/A conversion function of the analog output part ( Page 411 When Using the D/A Conversion Function)
• Pulse output function of the pulse output part ( Page 414 When Using the Pulse Output Function)
• Logging function of the logging control part ( Page 417 When Using the Logging Function)
System configuration
Power supply
module
CPU module
Master module
FTP server
for saving logging data
• CPU module: R120CPU
• Master module: RJ71GN11-T2 (X0 to X1F/Y0 to Y1F)
• Input module: RX10 (X20 to X2F)
• Main module: NZ2GN2S-D41P01
• Extension module: NZ2EX2S-D41A01
14 SAMPLE CIRCUIT IN CC-LINK IE TSN COMMUNICATION MODE
396
Ó
Pulse count function
×
Logging function
X1
X2
0
12
Counter
Logging the counter value
TSN HUB
Ò
Inverted output function
ON
X0
OFF
ON
Y0
OFF
3
4
Ö
ON width:
Ô
A/D conversion function
CH0: Voltage output
Digital value setting
IP address: 192.168.3.250
Õ
D/A conversion function
Digital value setting
CH0: Voltage output
Pulse output function
100μs
OFF width:
100μs
Y1
[1 pulse]
[1 pulse]
Total 100 pulse output