Chapter 5 Differences In Flow At Machine Startup Adjustment; Differences In Operation Flow; Difference In Operation Mode - Mitsubishi Electric LE-40MT Series Handbook

Tension controller
Table of Contents

Advertisement

5
DIFFERENCES IN FLOW AT MACHINE
STARTUP ADJUSTMENT
This section describes the differences in flow at machine startup adjustment.
5.1

Differences in Operation Flow

An operation flowchart is shown below. There is no difference in the basic operation flow till the test operation among LE-
40MTA, B(-E), LE-30CTN(A), and LE7-40GU-L.
(1) Controller
installation
and wiring
(4) Operation
verification by
automatic operation
5.2

Difference in Operation Mode

LE7-40GU-L has the following operation modes.
Mode
Explanation
Initial setting mode
Initial setting mode at startup of equipment
Adjustment Mode
Parameter detail setting mode
Operation mode
Yes
Initial setting mode
• The LE7-40GU-L has an initial setting mode and is set in the initial setting mode from the factory shipment until the initial
setting completion operation is executed. In the initial setting mode, the setting items that are indispensable for the
operation of the tension controller are set in order. The LE-30CTN(A) does not have a function corresponding to the initial
setting mode.
• The items that can be set in the initial setting mode differ between LE-40MTA, B(-E) and LE7-40GU-L. The parameters that
can be set in the initial setting mode are compared below. The parameters that can not be set should be changed in
adjustment mode.
Parameter
Password registration
Tension display unit setting
Selection of control target reel
Number of control target reels (selection of two-reel's
switching function)
Taper setting
Actuator setting
Usage of stall function
I/O terminal function setting
Full scale tension setting
Zero span adjustment of tension detector
(2) Controller settings
• Initial setting
• Tension detector setting
(5) Parameter
setting as needed
Setting location
LE-40MTA, B(-E)
Initial Setting
Initial setting/engineer
Initial setting/engineer
Initial setting/engineer
Initial setting/engineer
Initial setting/engineer
Initial setting/engineer
Initial setting/engineer
Initial setting/engineer
Initial setting/engineer
5 DIFFERENCES IN FLOW AT MACHINE STARTUP ADJUSTMENT
(3) Drive system
verification by
manual operation
Stop
Function availability
LE-40MTA, B(-E)
LE7-40GU-L
Adjustment
Initial setting/adjustment
Adjustment
Initial setting/adjustment
Adjustment
Adjustment*
Adjustment
Adjustment
Initial setting/adjustment
Initial setting/adjustment
5.1 Differences in Operation Flow
LE-30CTN(A)
*1
23
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Le-30ctnLe-30ctnaLe7-40gu-l

Table of Contents