76 Chapter 8 Replacing basic chassis components
5
To replace the server cover
Step
1
2

Removing and replacing the processor air duct

You must remove the air duct to access the processor assembly, four-fan
assembly, and the memory modules. Because the processor air duct
channels the airflow within the chassis, be sure to reinstall the air duct
before installing the chassis cover.
Requirements
You need a Phillips (cross head) screwdriver, #1 and #2 bit.
Copyright © 2007, Nortel Networks
.
Server cover
Lift the cover straight up to remove it from the platform.
Action
Place the cover over the chassis so that the side edges of the cover
sit just inside the chassis sidewalls. The front of the cover is about
an eighth of an inch from the sheet metal at the front of the chassis.
Refer to
"Server cover" (page
Press down slightly on the chassis cover behind the DVD combo
drive area and slide the cover forward until it clicks into place.

Nortel CallPilot

1005r Server Maintenance and Diagnostics

NN44200-704 01.06 Standard

5.0 19 July 2007
—End—
76).
—End—