92 Chapter 8 Replacing basic chassis components
6
7
8
9
10
11
12
13
14
15
Copyright © 2007, Nortel Networks
.
Memory DIMM locations
Push the clips at each end of the DIMM sockets outward to the
open position.
Remove all the DIMMs.
Holding each DIMM by the edges, remove it from the antistatic
envelope.
Position the DIMM above the socket and align the small notch in the
bottom edge of the DIMM with the keys in the socket.
Insert the bottom edge of the DIMM into the socket.
Push down on the top edge of the DIMM until the retaining clips snap
into place. The retaining clips must be fully closed for the DIMM to
make proper contact with the server board.
Install the other three DIMMs.
Replace the processor air duct.
Replace the chassis cover.
Plug in all peripheral devices and AC power.
Nortel CallPilot
1005r Server Maintenance and Diagnostics
NN44200-704 01.06 Standard
5.0 19 July 2007