To configure an LSI320-1 RAID system
Step
To configure RAID, do the following:
1
2
3
4
5
6
7
8
9
Copyright © 2007, Nortel Networks
.
Configuring RAID using LSI320-1 controller and Ctrl+M 99
Action
Turn on the server and press Ctrl+M when prompted during system
bootup.
Note: The Ctrl+M utility can take up to 1 minute to launch with
1L37 firmware. The system can appear frozen. Do not reset.
From the Management menu, select Objects and press Enter.
From the Objects menu, select Adapter and press Enter.
From the Adapter menu, select Factory Default and press Enter.
Select Yes to confirm the selection and press Enter.
Result: The system displays ForceBoot Option is Enabled Press
Any Key.
Press any key.
Result: The system displays BOOT Parameters Changed. Press
Ctrl-Alt-Delete to REBOOT.
Press Ctrl+Alt+Delete when prompted to restart system.
During bootup, press Ctrl+M to re-enter the RAID setup utility.
From the Management menu, select Objects → Adapter, and then
ensure the Adapter 1 values are set as follows:
FlexRAID PowerFail: Enabled
Fast Initialization: On
Disk Spin up Timings: 1 disk every 6 secs
Cache Flush Timings: Every 4 Seconds
Rebuild Rate: 30%
Alarm Control: Enabled (There is no audible alarm)
Other Adapter Options:
Emulation: Mass Storage
— Auto Rebuild: Disabled
— Initiator ID: 7
— Multiple PCI Delayed Trans: Disabled
— Force Boot: On
— Coercion Algorithm: 1GB-way
— CC Restoration: Enabled
Note: The Coercion Algorithm must be set properly. When
changed, it cannot be changed again without clearing the
configuration.