Perform the following procedure only if the firmware version is not the version
identified in this section.
To upgrade or downgrade the RAID firmware
Step
The firmware of the RAID card is upgraded through a flash process. The
flash process is initiated by running the RAID card firmware update utility
on the CallPilot DVD.
1
2
3
4
Copyright © 2007, Nortel Networks
.
From the MegaRAID console, choose Adapter > Properties.
Review the information on the screen. The LSI320-1 controller
firmware must be 1L37.
If the firmware is not correct, perform a firmware update. For
instructions, see
"To upgrade or downgrade the RAID firmware"
(page
97).
Action
Insert the CallPilot Image DVD for the platform into the DVD combo
drive.
Power down the CallPilot server.
Restart the CallPilot server.
Result: The server boots from the DVD and the Startup Menu
appears.
1.Install CallPilot 5.0 1005r server image and exit to
DOS (recommended).
2.Install CallPilot 5.0 1005r server image and exit to
DOS (FACTORY ONLY).
3.Utilities (BIOS, Firmware, etc...)
Enter 3 and press Enter to run Utilities (BIOS, Firmware, etc...) from
the Startup.
Result: The Nortel CallPilot Image Menu appears.
1.1005r server BIOS update
2.1005r server FRU/SDR firmware update
3.1005r server Board Management Controller (BMC)
firmware update
4.LSI320-1 RAID controller firmware update
5.1005r system Utilities and SEL Viewer
6.Go to DOS
Nortel CallPilot
1005r Server Maintenance and Diagnostics
NN44200-704 01.06 Standard
5.0 19 July 2007
Verifying the RAID firmware 97
—End—