78 Chapter 7 Replacing basic chassis components
To replace the server cover
Step
1
2
3
Removing and replacing the processor air duct
You must remove the air duct to access the processor assembly and the two
system fans. Because the processor air duct channels the airflow within the
chassis, reinstall the air duct before installing the server cover.
Requirements
You need a Phillips (cross head) screwdriver, #1 and #2 bits.
To remove the processor air duct
Step
1
2
3
4
Copyright © 2007, Nortel Networks
.
Action
Place the cover over the chassis so that the side edges of the cover
sit just inside the chassis sidewalls. The front of the cover is about
an eighth of an inch from the sheet-metal at the front of the chassis.
Press down slightly on the server cover behind the DVD-ROM drive
area and slide the cover forward until it clicks into place.
Plug in the peripheral devices and Ethernet cables, connect the AC
power cords, and restart the server.
Action
Power down the server, unplug all peripheral devices and Ethernet
cables, and disconnect the AC power.
Attach the ESD strap to your wrist and attach the other end to a
known grounded connection.
Remove the server cover. For more details, see
replacing the server cover" (page
Remove the screw at the top of the air duct.
Nortel CallPilot
600r Server Maintenance and Diagnostics
NN44200-703 01.04 Standard
5.0 25 April 2007
—End—
—End—
77).
"Removing and