● Before powering off the server, ensure that server data has been saved and
● Powering off a server will interrupt all services and programs running on it.
● After the server is powered off, wait for at least 1 minute and then switch on
● The "power-off" mentioned here is an operation performed to change the
The methods for powering off the server are as follows:
Issue 46 (2022-12-28)
NO TICE
drive services have been stopped. Do not forcibly power off the server when
read and write operations are being performed on drives. Otherwise, bad
sectors may occur, compromising data sources.
Therefore, before powering off a server, ensure that all services and programs
have been stopped or migrated to other servers.
the PSUs again.
server to the standby state.
Power off the server to the standby state.
NO TE
● When the power indicator is steady yellow, the server is in the standby state.
● Forced power-off may damage user programs or unsaved data. Exercise caution
when performing this operation.
Connect a keyboard, video, and mouse (KVM) to the server and shut
down the operating system of the server using the KVM.
When the server is in power-on state, pressing the power button on the
server front panel can power off the server gracefully.
NO TE
If the server OS is running, shut down the OS according to the onscreen
instructions.
For details, see
When the server is in power-on state, holding down the power button on
the server front panel for six seconds can power off the server forcibly.
For details, see
Log in to the Remote Virtual Console of the server, and shut down the
operating system.
For details about how to log in to the Remote Virtual Console, see
Opening the Remote Virtual
Power off the server using the iBMC WebUI. For details, see
Off the
Server.
Power off the server using the iBMC CLI.
Log in to the iBMC CLI. For details, see
Run the ipmcset -d powerstate -v 0 command on the iBMC CLI.
Power off the server completely.
If the server has been powered off and is in the standby state, remove the
power cable to disconnect the external power supply. After that, the server is
powered off completely.
Copyright © Huawei Technologies Co., Ltd.
2.4 Indicators and
Buttons.
2.4 Indicators and
Buttons.
Console.
4 Powering On and Off the Server
9.3 Logging In to the iBMC
9.7
4.2 Powering
CLI.
119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V100r003

Table of Contents