The original drive and its mirror must be of the same type and must have
the same partitioning and the same SCSI ID.
Also refer to the "Virtual Disks" manual.
or
RAID operation with the RAIDmaster controller (CS31)
OLR is allowed in RAID 1 arrays and in RAID 5 arrays. Also refer to the
"RAIDmaster - System Administrator's Guide".
OLR shuttle criteria
3 1
" OLR shuttle with handle
/2
Automatically addressable drives (slot coding with Flexprint on the inside of the
OLR shuttle)
LEDs on the front panel of the OLR shuttle
If any of these criteria are not met, only SNI service personnel is allowed
!
to replace a defective drive.
6.2

Identifying a defective drive

The red LED on the OLR housing identifies a disabled drive which can be replaced.
You can identify the defective drive with the aid of XConfig (on a graphical terminal)
or SYSADM (on an alphanumeric terminal). Under XConfig, defective or disabled
drives are shown in red; under SYSADM, an error messages appears for each
defective or disabled drive.
Another way of identifying defective drives is to use the RAIDmaster Storage Manager
(see the "RAIDmaster - System Administrator's Guide").
Using XConfig to identify a defective hard drive
To use XConfig you need a graphical monitor.
U24802-J-Z146-2-7600
Online replacement (OLR)
RM400 C Models
6
65