Siemens SIMATIC RTLS System Manual
Hide thumbs Also See for SIMATIC RTLS:
Table of Contents

Advertisement

Quick Links

SIMATIC RTLS
System Manual
04/2019
C79000-G8976-C577-01
Introduction
Safety notices
System overview
Planning an RTLS system
Anchors
Gateways
Transponder
Accessories
System integration
System diagnostics
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RTLS

  • Page 1 Introduction Safety notices System overview SIMATIC RTLS Planning an RTLS system Anchors Gateways System Manual Transponder Accessories System integration System diagnostics 04/2019 C79000-G8976-C577-01...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction..............................9 Safety notices .............................11 System overview ............................13 System overview ........................13 Planning an RTLS system ..........................17 Basics of application planning....................17 Field data of anchors, gateways and transponders ...............17 Installation guidelines......................17 Chemical resistance of anchors, gateways and transponders..........17 Directives on electromagnetic compatibility ................17 Anchors ..............................19 SIMATIC RTLS4030A ......................19 5.1.1...
  • Page 4 Table of contents 5.2.3 Technical specifications ......................40 5.2.4 Approvals ..........................41 5.2.4.1 UL............................44 SIMATIC RTLS4420A ......................45 5.3.1 Device description........................45 5.3.1.1 Characteristics ........................45 5.3.1.2 Order data RTLS4420A ......................45 5.3.1.3 Pin assignment........................46 5.3.1.4 LED status indicator .......................47 5.3.1.5 Dimension drawing.........................48 5.3.1.6 Troubleshooting ........................49 5.3.2 Installation &...
  • Page 5 Table of contents SIMATIC RTLS4330G......................84 6.2.1 Device description........................84 6.2.1.1 Characteristics ........................84 6.2.1.2 Order data RTLS4330G ......................84 6.2.1.3 Pin assignment........................85 6.2.1.4 LED status indicator .......................87 6.2.1.5 Dimension drawing.........................88 6.2.1.6 Troubleshooting ........................88 6.2.2 Installation & Operation......................89 6.2.2.1 Notes on installation.......................89 6.2.2.2 Installation options .........................90 6.2.2.3 Ethernet..........................92 6.2.2.4...
  • Page 6 Table of contents 7.1.1.1 Characteristics ........................125 7.1.1.2 Order data RTLS4030T......................125 7.1.1.3 LED status indicator ......................126 7.1.1.4 Dimension drawing.......................126 7.1.2 Installation & Operation......................126 7.1.2.1 Notes on installation......................126 7.1.2.2 Cleaning and maintenance ....................127 7.1.3 Technical specifications .......................128 7.1.4 Approvals ..........................129 7.1.4.1 UL............................132 SIMATIC RTLS4060T ......................133 7.2.1 Device description........................133...
  • Page 7 Installation & Operation......................169 7.6.2.1 Cleaning and maintenance ....................169 7.6.3 Technical specifications .......................170 7.6.4 Approvals ..........................171 7.6.4.1 UL............................174 SIMATIC RTLS PCB OEM AX .....................175 7.7.1 Device description........................175 7.7.1.1 Order data RTLS PCB OEM AX ..................175 7.7.1.2 Pin assignment........................175 7.7.1.3 LED status indicator ......................176 7.7.1.4...
  • Page 8 Table of contents Accessories ..............................197 System integration............................199 System diagnostics...........................201 Index.................................203 System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 9: Introduction

    Additional information (https://support.industry.siemens.com/cs/us/en/ps/25277) Trademarks SIMATIC RTLS ® is a registered trademark of the Siemens AG. Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support offers support at the following Internet address: (https:// support.industry.siemens.com/cs/us/en/)
  • Page 10 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
  • Page 11: Safety Notices

    ● For communication via non-secure networks use additional devices with VPN functionality to encrypt and authenticate the communication. ● Terminate the management connections properly (SIMATIC RTLS Locating Manager and its clients). ● Keep the firmware up to date. Check regularly for security updates for the device. You can find information on this at the Industrial Security (https://www.industry.siemens.com/topics/...
  • Page 12 Safety notices ● Use passwords with a high password strength. ● Make sure that all passwords are protected and inaccessible to unauthorized persons. ● Do not use the same password for different users and systems. Physical access Note the following security recommendations for physical access to the devices: ●...
  • Page 13: System Overview

    This makes SIMATIC RTLS a crucial component of the digital infrastructure in the plant of the future. SIMATIC RTLS is used to implement localization tasks that require a high level of accuracy in large indoor or outdoor spaces.
  • Page 14 The quality of the data collected in production control and logistics increases significantly through the use of SIMATIC RTLS. In addition to identification of objects and vehicles, position data is available in real time. The localization platform covers entire buildings, halls and factory sites almost completely and ensures a degree of transparency that could not be achieved with established technology so far.
  • Page 15 3.1 System overview Easy integration into your automation level SIMATIC RTLS can be easily integrated into the IT landscape by means of the SIMATIC Locating Manager software. This ensures you will have an integrated software architecture and significant savings during engineering, commissioning and maintenance. A wide range of software functions (e.g.
  • Page 16 System overview 3.1 System overview System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 17: Planning An Rtls System

    Planning an RTLS system Basics of application planning Field data of anchors, gateways and transponders Installation guidelines Chemical resistance of anchors, gateways and transponders Directives on electromagnetic compatibility System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 18 Planning an RTLS system 4.5 Directives on electromagnetic compatibility System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 19: Anchors

    Anchors SIMATIC RTLS4030A 5.1.1 Device description 5.1.1.1 Characteristics SIMATIC RTLS4030A Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital output General The device is the home location for localiza‐ tion in the RTLS localization system. It collects the localization data and sends it to the localization server.
  • Page 20: Pin Assignment

    Anchors 5.1 SIMATIC RTLS4030A Table 5-2 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway 6GT2790-0BE30 Connecting cable for connection to wide-range power supply unit for anchor / gateway...
  • Page 21: Led Status Indicator

    Anchors 5.1 SIMATIC RTLS4030A Meaning Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA 5.1.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
  • Page 22: Dimension Drawing

    Anchors 5.1 SIMATIC RTLS4030A Meaning RADIO LED Flashes yellow when the radio signal of the device to the RTLS localization system is active SERVER LED Lights up blue when the device is connected to the local network 5.1.1.5 Dimension drawing Figure 5-1 Dimension drawing SIMATIC RTLS4030A - All dimensions specified in millimeters System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 23: Troubleshooting

    Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
  • Page 24: Installation Options

    Anchors 5.1 SIMATIC RTLS4030A When the supply voltage is connected to the power plug, all LEDs flash briefly for a moment. The POWER LED lights up as soon as voltage is present. Make sure that a cable fuse is installed in front of the device. Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications".
  • Page 25 Anchors 5.1 SIMATIC RTLS4030A Figure 5-2 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
  • Page 26: Operation

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
  • Page 27: Technical Specifications

    Anchors 5.1 SIMATIC RTLS4030A 5.1.3 Technical specifications Table 5-3 Technical specifications of the anchor RTLS4030A 6GT2701-5DA03 Product name SIMATIC RTLS4030A PULSE radio frequencies Wireless method IEEE 802.15.4-2011 UWB Transmission speed 6.8 Mbps Operating frequency rated value 3100 MHz … 4800 MHz 6000 MHz …7000 MHz Transmit power 0.001 ...
  • Page 28: Approvals

    PX0412/03P 5.1.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 29 Anchors 5.1 SIMATIC RTLS4030A Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems...
  • Page 30 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4030A (MLFB 6GT2701-5DA03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 31 Anchors 5.1 SIMATIC RTLS4030A (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement. 5.1.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ.
  • Page 32: Simatic Rtls4330A

    Anchors 5.2 SIMATIC RTLS4330A SIMATIC RTLS4330A 5.2.1 Device description 5.2.1.1 Characteristics SIMATIC RTLS4330A Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital output General The device is the home location for localiza‐ tion in the RTLS localization system. It collects the localization data and sends it to the localization server.
  • Page 33: Pin Assignment

    Anchors 5.2 SIMATIC RTLS4330A 5.2.1.3 Pin assignment 3-pin plug-in connector Buccaneer® PX0412/03P Connectors: SA3350/1 Sealing cover: PX0480 System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 34: Led Status Indicator

    Anchors 5.2 SIMATIC RTLS4330A Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA 5.2.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
  • Page 35: Dimension Drawing

    Dimension drawing SIMATIC RTLS4330A - All dimensions specified in millimeters 5.2.1.6 Troubleshooting If a fault occurs, inspect the device for the following errors and take appropriate measures. If there are other undefined errors, please contact Siemens Support (https:// support.industry.siemens.com/cs/start?lc=en-US). Error detection...
  • Page 36: Installation & Operation

    Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
  • Page 37: Installation Options

    Anchors 5.2 SIMATIC RTLS4330A Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
  • Page 38 Anchors 5.2 SIMATIC RTLS4330A Figure 5-4 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
  • Page 39: Operation

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 40: Technical Specifications

    Anchors 5.2 SIMATIC RTLS4330A Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids. 5.2.3 Technical specifications Table 5-6 Technical specifications of the anchor RTLS4330A 6GT2701-5EA03 Product name SIMATIC RTLS4330A PULSE radio frequencies Wireless method IEEE 802.15.4-2001 UWB Transmission speed 6.8 Mbps Operating frequency rated value...
  • Page 41: Approvals

    Supply voltage 5.2.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 42 Anchors 5.2 SIMATIC RTLS4330A Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems...
  • Page 43 Anchors 5.2 SIMATIC RTLS4330A FCC information Siemens SIMATIC RTLS4330A (MLFB 6GT2701-5EA03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 44 Anchors 5.2 SIMATIC RTLS4330A 5.2.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ. LOC. The products meet the requirements of the following standards: Document Title UL 60079-0 Hazardous areas CSA C22.2 NO. 60079-0 Part 0: Equipment - General requirements UL 60079-7 Hazardous areas...
  • Page 45: Simatic Rtls4420A

    Anchors 5.3 SIMATIC RTLS4420A SIMATIC RTLS4420A 5.3.1 Device description 5.3.1.1 Characteristics SIMATIC RTLS4420A Characteristics ① Design Status indicators (LEDs) ② Antenna connector for RP SMA antenna ③ Connector for supply voltage and digital out‐ puts General The device is the home location for localization in the RTLS localization system.
  • Page 46: Pin Assignment

    Anchors 5.3 SIMATIC RTLS4420A Table 5-8 Accessories order data (not included in scope of delivery) Article number Antenna with N-M connector 4.5 dBi 6GT2706-0BA00 IWLAN antenna ANT795-6MN 6GK5795-6MN10-0AA6 Mounting set for ANT795-6MN 6GK5795-6MN01-0AA6 including mounting aid, angle adapter, N-Connect, fixing screws, Compact instructions Flexible connecting cable (e.g.
  • Page 47: Led Status Indicator

    Anchors 5.3 SIMATIC RTLS4420A Output voltage: 0 (switched off) or input voltage (switched on) Maximum output current: 100 mA P2 - Antenna - RP-SMA connection Description Antenna Shielding GND, shielding 5.3.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
  • Page 48: Dimension Drawing

    Anchors 5.3 SIMATIC RTLS4420A RUN LED (D2) Meaning Is off when the device is inactive Flashes regularly in green when an error is indicated Is on when the device is in operation. 5.3.1.5 Dimension drawing Figure 5-5 Dimension drawing SIMATIC RTLS4420A - All dimensions specified in millimeters System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 49: Troubleshooting

    The green LED (RUN) flashes during Error in the device Reset by switching the device off and on operation. again; if the error occurs again, contact SIEMENS Service. 5.3.2 Installation & Operation 5.3.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
  • Page 50: Technical Specifications

    Anchors 5.3 SIMATIC RTLS4420A Supply voltage When the supply voltage is connected at the "Power" input, all LEDs flash briefly for a moment. The POWER LED lights up permanently in green as soon as voltage is present. Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications".
  • Page 51: Approvals

    To restore the factory settings 5.3.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 52 Anchors 5.3 SIMATIC RTLS4420A RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
  • Page 53 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4420A (MLFB 6GT2701-2CA02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 54 Anchors 5.3 SIMATIC RTLS4420A (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
  • Page 55: Simatic Rtls4430A

    Anchors 5.4 SIMATIC RTLS4430A The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] SIMATIC RTLS4430A 5.4.1 Device description 5.4.1.1 Characteristics SIMATIC RTLS4430A Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital outputs General The device is the home location for localiza‐...
  • Page 56: Pin Assignment

    Anchors 5.4 SIMATIC RTLS4430A Table 5-11 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway 6GT2790-0BE30 Connecting cable for connection to wide-range power supply unit for anchor / gateway...
  • Page 57: Led Status Indicator

    Anchors 5.4 SIMATIC RTLS4430A Meaning Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA 5.4.1.4 LED status indicator The operating states of the anchor are indicated by the LEDs. The states can be off , on flashing .
  • Page 58: Dimension Drawing

    Anchors 5.4 SIMATIC RTLS4430A Meaning RADIO LED Flashes yellow when the radio signal of the device to the RTLS localization system is active SERVER LED Lights up blue when the device is connected to the local network 5.4.1.5 Dimension drawing Figure 5-6 Dimension drawing SIMATIC RTLS4430A - All dimensions specified in millimeters System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 59: Troubleshooting

    Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
  • Page 60: Installation Options

    Anchors 5.4 SIMATIC RTLS4430A Supply voltage When the supply voltage is connected at the "Power" input, all LEDs light briefly for a moment. The POWER LED lights up permanently in green as soon as voltage is present. Make sure that a cable fuse is installed upstream of the device. Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications".
  • Page 61 Anchors 5.4 SIMATIC RTLS4430A Figure 5-7 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
  • Page 62: Operation

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
  • Page 63: Technical Specifications

    Titanium gray Power plug 3-pin plug-in connector with screw-type terminal Bulgin Buc‐ caneer® PX0412/03P 5.4.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 64 Anchors 5.4 SIMATIC RTLS4430A Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
  • Page 65 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4430A (MLFB 6GT2701-5CA02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 66 Anchors 5.4 SIMATIC RTLS4430A Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 67 Anchors 5.4 SIMATIC RTLS4430A UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X...
  • Page 68 Anchors 5.4 SIMATIC RTLS4430A System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 69: Gateways

    Gateways SIMATIC RTLS4030G 6.1.1 Device description 6.1.1.1 Characteristics SIMATIC RTLS4030G Characteristics ① Design Status indicators (LEDs) ② Connector for power supply over mains connection ③ Ethernet port; Alternative power supply using Power over Ethernet (PoE) General The device is the home location for localiza‐ tion in the RTLS localization system.
  • Page 70: Pin Assignment

    Gateways 6.1 SIMATIC RTLS4030G Table 6-2 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Bayonet connector (Amphenol RCP-00BMMS-TLM7001) made of plastic 6GT2790-0CB00 for RJ45 connector for cable mounting (IP65) at gateway Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway...
  • Page 71 Gateways 6.1 SIMATIC RTLS4030G Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA Figure 6-1 RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 72: Led Status Indicator

    Gateways 6.1 SIMATIC RTLS4030G 6.1.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs. The states can be off , on and flashing . Meaning POWER LED Lights up green when power is supplied to the device through the mains cable POWER LED Flashes red once per second when there is an undervoltage at the device RADIO LED...
  • Page 73: Dimension Drawing

    Gateways 6.1 SIMATIC RTLS4030G 6.1.1.5 Dimension drawing Figure 6-2 Dimension drawing SIMATIC RTLS4030G - All dimensions specified in millimeters 6.1.1.6 Troubleshooting Error detection Cause of the error Troubleshooting Device does not respond, all LEDs are The device is not connected or the pow‐ Check the supply voltage of the device.
  • Page 74: Installation & Operation

    Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
  • Page 75: Installation Options

    Gateways 6.1 SIMATIC RTLS4030G Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
  • Page 76 Gateways 6.1 SIMATIC RTLS4030G Figure 6-3 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
  • Page 77: Ethernet

    Gateways 6.1 SIMATIC RTLS4030G Installation with support - Corner installation Follow the steps below to mount the device to a corner: 1. Use the corner support as template and draw the bore holes on the corner. 2. Drill the holes with a suitable device. 3.
  • Page 78: Cleaning And Maintenance

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
  • Page 79: Approvals

    Amphenol LTW RCP-00AMMA-TLM7001 6.1.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 80 Gateways 6.1 SIMATIC RTLS4030G RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
  • Page 81 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4030G (MLFB 6GT2701-5DB03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 82 Gateways 6.1 SIMATIC RTLS4030G Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 83 Gateways 6.1 SIMATIC RTLS4030G UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X...
  • Page 84: Device Description

    Gateways 6.2 SIMATIC RTLS4330G SIMATIC RTLS4330G 6.2.1 Device description 6.2.1.1 Characteristics SIMATIC RTLS4330G Characteristics ① Design Status indicators (LEDs) ② Connector for supply voltage and digital output ③ Ethernet port; Alternative power supply using Power over Ethernet (PoE) General The device is the home location for localiza‐ tion in the RTLS localization system.
  • Page 85: Pin Assignment

    Gateways 6.2 SIMATIC RTLS4330G Article number Holder for ceiling suspension of anchor/gateway 6GT2790-0BE20 Holder for corner/mast mounting of anchor/gateway 6GT2790-0BE30 6.2.1.3 Pin assignment Ethernet socket RJ45 The device may only be connected to the Ethernet via the plug-in connectors shown below. When connecting the Ethernet cable, ensure that the twist-lock connectors are correctly secured.
  • Page 86 Gateways 6.2 SIMATIC RTLS4330G Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA Connection socket Amphenol LTW RCP-5SPFFH-TCU7001 Figure 6-4 RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 87 Gateways 6.2 SIMATIC RTLS4330G 6.2.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs. The states can be off , on and flashing . Display Meaning POWER LED Lights up green when power is supplied to the device through the mains cable POWER LED Flashes red once per second when there is an undervoltage at the device RADIO LED...
  • Page 88: Dimension Drawing

    Dimension drawing SIMATIC RTLS4330G - All dimensions specified in millimeters 6.2.1.6 Troubleshooting If a fault occurs, inspect the device for the following errors and take appropriate measures. If there are other undefined errors, please contact Siemens Support (https:// support.industry.siemens.com/cs/start?lc=en-US). Error detection...
  • Page 89: Installation & Operation

    Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
  • Page 90 Gateways 6.2 SIMATIC RTLS4330G Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
  • Page 91 Gateways 6.2 SIMATIC RTLS4330G Figure 6-6 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
  • Page 92: Cleaning And Maintenance

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
  • Page 93: Technical Specifications

    Gateways 6.2 SIMATIC RTLS4330G 6.2.3 Technical specifications Table 6-6 Technical specifications of the gateway RTLS4330G 6GT2701-5EB03 Product name SIMATIC RTLS4330G PULSE radio frequencies Wireless method IEEE 802.15.4-2001 UWB Transmission speed 6.8 Mbps Operating frequency rated value 3100 MHz ... 4800 MHz 6000 MHz ...
  • Page 94: Approvals

    Amphenol LTW PCP-00AMMA-TLM7001 6.2.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 95 Gateways 6.2 SIMATIC RTLS4330G The products described in these operating instructions meet the requirements of EU directive 2014/30/EU "Electromagnetic Compatibility" according to the designated standards for the following areas of application. Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ●...
  • Page 96 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4330G (MLFB 6GT2701-5EB03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 97 Gateways 6.2 SIMATIC RTLS4330G (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement. 6.2.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ.
  • Page 98: Device Description

    Gateways 6.3 SIMATIC RTLS4420G SIMATIC RTLS4420G 6.3.1 Device description 6.3.1.1 Characteristics SIMATIC RTLS4420G Characteristics ① Design Status indicators (LEDs) ② Antenna connector for RP SMA antenna ③ Connector for supply voltage and digital outputs General The device is the home location for localiza‐ tion in the RTLS localization system.
  • Page 99: Pin Assignment

    Gateways 6.3 SIMATIC RTLS4420G Table 6-8 Accessories order data (not included in scope of delivery) Article number Antenna with N-M connector 4.5 dBi 6GT2706-0BA00 IWLAN antenna ANT795-6MN 6GK5795-6MN10-0AA6 Mounting kit for ANT795-6MN 6GK5795-6MN01-0AA6 including mounting aid, angle adapter, N-Connect Fixing screws, Compact instructions Flexible connecting cable (e.g.
  • Page 100 Gateways 6.3 SIMATIC RTLS4420G Description Supply voltage Ethernet shield Digital output - Connector 6 A high-side switch switches the power supply to the digital output (pin 6). Output voltage: 0 (switched off) or input voltage (switched on) Maximum output current: 100 mA P2 - Antenna - RP-SMA plug-in connector Description Antenna...
  • Page 101 Gateways 6.3 SIMATIC RTLS4420G Description Differential Ethernet receive data - 4, 5, 7, 8 Not connected Shield Grounding Description No connection Yellow 10 MBit Green 100 MBit Description No activity Yellow Half duplex activity Green Full duplex activity 6.3.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs.
  • Page 102: Dimension Drawing

    Gateways 6.3 SIMATIC RTLS4420G 6.3.1.5 Dimension drawing Figure 6-7 Dimension drawing SIMATIC RTLS4420G - All dimensions specified in millimeters System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 103: Installation & Operation

    The green LED (RUN) flashes during Error in the device Reset by switching the device off and on operation. again; if the error occurs again, contact SIEMENS Service. 6.3.2 Installation & Operation 6.3.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
  • Page 104: Technical Specifications

    Gateways 6.3 SIMATIC RTLS4420G Check whether the rated voltage of the power supply corresponds to the values in the section "Technical specifications". CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
  • Page 105: Approvals

    Ethernet RJ45 Ethernet (10/100 MBit) Antenna connector RP SMA screw connector 6.3.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 106 Gateways 6.3 SIMATIC RTLS4420G The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 1 July 2011, pages 88-110 ●...
  • Page 107 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4420G (MLFB 6GT2701-2CB02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 108 Gateways 6.3 SIMATIC RTLS4420G can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
  • Page 109: Device Description

    Gateways 6.4 SIMATIC RTLS4430G The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X AEx tc IIIC TXX °C Dc, Ex tc IIIC TXX °C Dc X -40 °C <...
  • Page 110: Pin Assignment

    Gateways 6.4 SIMATIC RTLS4430G 6.4.1.2 Order data RTLS4430G Table 6-10 Order data RTLS4430G Article number SIMATIC RTLS4430G 6GT2701-5CB02 SIMATIC RTLS4430G specially based for CD 6GT2701-5CB02-0AX0 Table 6-11 Accessories order data (not included in scope of delivery) Article number Power cable (Bulgin 400 Series Buccaneer® PX0410/03S) 6GT2791-2AH50 3-pin, 5 m Bayonet connector (Amphenol RCP-00BMMS-TLM7001) made of plastic...
  • Page 111 Gateways 6.4 SIMATIC RTLS4430G Plug-in connector for power, digital output 3-pin plug-in connector Buccaneer® PX0412/03P Connectors: SA3350/1 Sealing cover: PX0480 System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 112 Gateways 6.4 SIMATIC RTLS4430G Description Mains supply (red) 8 ... 30 V DC Grounding terminal (black) GND (0 V) Digital output (brown) Switched input voltage, max. current 200 mA Connector Amphenol LTW RCP-5SPFFH-TCU7001 Figure 6-8 RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 6.4.1.4 LED status indicator The operating states of the gateways are indicated by the LEDs.
  • Page 113: Dimension Drawing

    Gateways 6.4 SIMATIC RTLS4430G Meaning LAN/SERVER LED Flashes blue once per second when the device is connected to the network but there is no connection to the RTLS localization server LAN/SERVER LED Is off when the device is not connected to the network 6.4.1.5 Dimension drawing Figure 6-9...
  • Page 114: Installation & Operation

    Make sure that the wiring is correct before you start up the device. Only use the cables described in the manual, supplied with the device or otherwise prescribed. SIEMENS AG is not liable for damages or functional limitations caused by the use of other cables.
  • Page 115 Gateways 6.4 SIMATIC RTLS4430G The device can be supplied with power via the Ethernet cable. In this case, the power plug should be tightly sealed to prevent moisture from penetrating. Do not supply the device with power via the power input and PoE at the same time. The device is a class 0 device according to PoE.
  • Page 116 Gateways 6.4 SIMATIC RTLS4430G Figure 6-10 Drilling pattern - All dimensions specified in millimeters. Installation with support - Ceiling installation Follow the steps below to mount the device to the ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2.
  • Page 117 Gateways 6.4 SIMATIC RTLS4430G Installation with support - Corner installation Follow the steps below to mount the device to a corner: 1. Use the corner support as template and draw the bore holes on the corner. 2. Drill the holes with a suitable device. 3.
  • Page 118: Technical Specifications

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
  • Page 119: Approvals

    Amphenol LTW RCP-00AMMA-TLM7001 6.4.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 120 Gateways 6.4 SIMATIC RTLS4430G Applied standard: ● EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to restriction of hazardous substances The products described in this document meet the requirements of the applied standards: Article 3 (1) a) Protection of health and safety ●...
  • Page 121 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4430G (MLFB 6GT2701-5CB02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 122 Gateways 6.4 SIMATIC RTLS4430G (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
  • Page 123 Gateways 6.4 SIMATIC RTLS4430G The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 124 Gateways 6.4 SIMATIC RTLS4430G System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 125: Characteristics

    Transponder SIMATIC RTLS4030T 7.1.1 Device description 7.1.1.1 Characteristics SIMATIC RTLS4030T Characteristics Design General The transponder is the mobile device for lo‐ calization in the RTLS localization system. It sends position data to anchors and gateways which transmit the data to the localization server.
  • Page 126: Led Status Indicator

    Transponder 7.1 SIMATIC RTLS4030T 7.1.1.3 LED status indicator The operating states of the transponder are indicated by the LEDs. The states can be off , and flashing . LED (green) Meaning Flashes green briefly when the device is ready for operation. Flashes green permanently when the device is moved.
  • Page 127: Cleaning And Maintenance

    The device may only be repaired by an authorized maintenance company or opened for other types of work. Improper opening or repairing of the device may result in risks for the user. Opening the device without permission renders the warranty of the Siemens AG null and void. System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 128: Technical Specifications

    Transponder 7.1 SIMATIC RTLS4030T Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products. 7.1.3 Technical specifications Table 7-2 Technical specifications of the transponder RTLS4030T 6GT2700-3DA03 Product name SIMATIC RTLS4030T PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2011 UWB Transmission speed 6.8 Mbps...
  • Page 129: Approvals

    Anthracite 7.1.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 130 Transponder 7.1 SIMATIC RTLS4030T Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems...
  • Page 131 Transponder 7.1 SIMATIC RTLS4030T FCC information Siemens SIMATIC RTLS4030T (MLFB 6GT2700-3DA03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 132 Transponder 7.1 SIMATIC RTLS4030T 7.1.4.1 UL HAZ. LOC. The SIMATIC Ident products meet the requirements of explosion protection according to UL HAZ. LOC. The products meet the requirements of the following standards: Document Title UL 60079-0 Hazardous areas CSA C22.2 NO. 60079-0 Part 0: Equipment - General requirements UL 60079-7 Hazardous areas...
  • Page 133: Simatic Rtls4060T

    Transponder 7.2 SIMATIC RTLS4060T SIMATIC RTLS4060T 7.2.1 Device description 7.2.1.1 Characteristics SIMATIC RTLS4060T Characteristics Design General The transponder is the mobile device for lo‐ calization in the RTLS localization system. It sends position data to anchors and gateways which transmit the data to the localization server.
  • Page 134 Transponder 7.2 SIMATIC RTLS4060T Description Color of the cable core Digital input 2 Orange Digital input 1 Yellow CAN L Green CAN H Blue Not used Violet Digital output Both digital device outputs can switch resistive, capacitive and inductive loads. The current is automatically limited to these functions.
  • Page 135: Dimension Drawing

    Transponder 7.2 SIMATIC RTLS4060T 7.2.1.4 Dimension drawing Figure 7-2 Dimension drawing SIMATIC RTLS4060T - All dimensions specified in millimeters 7.2.2 Installation & Operation 7.2.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
  • Page 136: Technical Specifications

    Transponder 7.2 SIMATIC RTLS4060T Connection of the cables Make sure that the wiring is correct before you start up the device. Supply voltage CAUTION Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
  • Page 137: Approvals

    Light grey (RAL 7035) Plug-in connector 8-pin plug-in connector – cable socket PX0410/08S/6065 7.2.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 138 Transponder 7.2 SIMATIC RTLS4060T The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 1 July 2011, pages 88-110 ●...
  • Page 139 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4060T (MLFB 6GT2700-6DE03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 140 Transponder 7.2 SIMATIC RTLS4060T can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
  • Page 141: Simatic Rtls4083T

    Transponder 7.3 SIMATIC RTLS4083T The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X AEx tc IIIC TXX °C Dc, Ex tc IIIC TXX °C Dc X -15 °C <...
  • Page 142: Order Data Rtls4083T

    Transponder 7.3 SIMATIC RTLS4083T 7.3.1.2 Order data RTLS4083T Table 7-6 Order data RTLS4083T Article number SIMATIC RTLS4083T 6GT2700-5DC03 Table 7-7 Accessories order data (not included in scope of delivery) Article number Charging station for 10 transponders 6GT2790-0DD00 with power plug for region: D / F / NL / ESP / B / A / S / FIN Charging station for 10 transponders 6GT2790-0DD01 with power plug for region: USA...
  • Page 143: Dimension Drawing

    Transponder 7.3 SIMATIC RTLS4083T 7.3.1.4 Dimension drawing Figure 7-3 Dimension drawing SIMATIC RTLS4083T - All dimensions specified in millimeters 7.3.2 Installation & Operation 7.3.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
  • Page 144: Operation

    Improper opening or repairing of the device may result in risks for the user. Opening the device without permission renders the warranty of the Siemens AG null and void. Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products.
  • Page 145: Approvals

    Titanium gray 7.3.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 146 Transponder 7.3 SIMATIC RTLS4083T RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
  • Page 147 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4083T (MLFB 6GT2700-5DC03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 148 Transponder 7.3 SIMATIC RTLS4083T IC information This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
  • Page 149: Simatic Rtls4084T

    Transponder 7.4 SIMATIC RTLS4084T The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X AEx tc IIIC TXX °C Dc, Ex tc IIIC TXX °C Dc X -20 °C <...
  • Page 150: Order Data Rtls4084T

    Transponder 7.4 SIMATIC RTLS4084T 7.4.1.2 Order data RTLS4084T Table 7-9 Order data RTLS4084T Article number SIMATIC RTLS4084T 6GT2700-7DC03 including 4 x SAFT 3 V lithium batteries (already installed) 7.4.1.3 LED status indicator, display & function key The operating states of the transponder are indicated by the LED. The LED can be green and red and have the states off , on , flashes .
  • Page 151: Installation & Operation

    Transponder 7.4 SIMATIC RTLS4084T Figure 7-4 Dimension drawing SIMATIC RTLS4084T - All dimensions specified in millimeters 7.4.2 Installation & Operation 7.4.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation. The devices can only be used in conjunction with the RTLS localization system. Setup, installation and use of the tools and clients of the RTLS localization system are described in the corresponding manuals.
  • Page 152: Replacing The Batteries

    Improper opening or repairing of the device may result in risks for the user. Opening the device without permission renders the warranty of the Siemens AG null and void. Do not clean the enclosure with liquids or abrasive, caustic or flammable cleaning products.
  • Page 153: Approvals

    Fastening clip, double-sided adhesive tape Enclosure Plastic housing Color Titanium gray 7.4.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 154 Transponder 7.4 SIMATIC RTLS4084T The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 1 July 2011, pages 88-110 ●...
  • Page 155 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4084T (MLFB 6GT2700-7DC03); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 156 Transponder 7.4 SIMATIC RTLS4084T Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 157 Transponder 7.4 SIMATIC RTLS4084T UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC. CL.I, DIV.2, GP.C,D T4 CL.II, DIV.2, GP.F,G T80 °C AEx ec IIB T4 Gc, Ex ec IIB T4 Gc X...
  • Page 158: Simatic Rtls4460T

    Transponder 7.5 SIMATIC RTLS4460T SIMATIC RTLS4460T 7.5.1 Device description 7.5.1.1 Characteristics SIMATIC RTLS4460T Characteristics ① Design Status indicators (LEDs) ② Antenna connector for RP SMA antenna ③ Connector for supply voltage and digital inputs General The transponder is the mobile device for lo‐ calization in the RTLS localization system.
  • Page 159 Transponder 7.5 SIMATIC RTLS4460T Article number Antenna cable, 3 m 6GT2791-6AH30 Flexible connecting cable (e.g. for connecting an antenna to an access point) 6XV1875-5CH10 6XV1875-5CH20 6XV1875-5CH50 7.5.1.3 Pin assignment P1 - Plug-in connector for power, digital output 16-pin plug-in connector WR-MPC4 0.33 mm open 1.31 mm Description...
  • Page 160 Transponder 7.5 SIMATIC RTLS4460T Digital output Both digital device outputs can switch resistive, capacitive and inductive loads. The current is automatically limited to these functions. The following must be observed for inductive loads (e.g. relays): Inductivities up to 32 H can be switched off without freewheeling diode D .
  • Page 161 Transponder 7.5 SIMATIC RTLS4460T 7.5.1.4 LED status indicator Possible LED states The operating states of the transponder are indicated by the LEDs. The states can be off , and flashing . RADIO LED (D1) Meaning Is off when the device is inactive Flashes once every 0.5 seconds when a test is conducted during device start.
  • Page 162 Transponder 7.5 SIMATIC RTLS4460T 7.5.1.5 Dimension drawing Figure 7-5 Dimension drawing SIMATIC RTLS4460T - All dimensions specified in millimeters 7.5.2 Installation & Operation 7.5.2.1 Notes on installation Before you install the devices, read this section carefully to ensure trouble-free installation and operation.
  • Page 163 Transponder 7.5 SIMATIC RTLS4460T Connection of the cables Make sure that the wiring is correct before you start up the device. Connection of the antenna Connect the antenna to the RP SMA connection (P2). The device must not be operated without an antenna.
  • Page 164 Mini blade-type fuse, 2 A 7.5.4 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ●...
  • Page 165 Transponder 7.5 SIMATIC RTLS4460T RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
  • Page 166 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4460T (MLFB 6GT2700-6CE02); FCC ID NXW-RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 167 Transponder 7.5 SIMATIC RTLS4460T (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d`en compromettre le fonctionnement.
  • Page 168 Transponder 7.6 SIMATIC RTLS PCB OEM AC The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] SIMATIC RTLS PCB OEM AC 7.6.1 Device description 7.6.1.1 Order data RTLS PCB OEM AC Table 7-14 Order data RTLS PCB OEM AC...
  • Page 169 7.6.1.4 Dimension drawing The UWB antenna is arranged diagonally standing up on the top side of the PCB. Figure 7-6 Dimension drawing SIMATIC RTLS PCB OEM AC - All dimensions specified in millimeters 7.6.2 Installation & Operation 7.6.2.1 Cleaning and maintenance The device may only be opened by suitably trained and qualified personnel.
  • Page 170 Transponder 7.6 SIMATIC RTLS PCB OEM AC Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void.
  • Page 171 Transponder 7.6 SIMATIC RTLS PCB OEM AC 6GT2700-8DF00-0AX1 PCB dimensions (L x W x H) 25 x 25 x 18 mm Antenna dimensions (L x W x H) 20.6 x 12.7 x 1.6 mm Weight Approx. 6 g Degree of protection IP00 7.6.4...
  • Page 172 Transponder 7.6 SIMATIC RTLS PCB OEM AC The products described in these operating instructions meet the requirements of EU directive 2014/30/EU "Electromagnetic Compatibility" according to the designated standards for the following areas of application. Article 3 (1) b) EMC ● ETSI EN 301 489-1...
  • Page 173 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM AC (MLFB 6GT2700-8DF00-0AX1); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 174 Transponder 7.6 SIMATIC RTLS PCB OEM AC Le présent appareil est conforme aux CNR d`Industrie Canada applicables aux appareils radio exempts de licence. L`exploitation est autorisée aux deux conditions suivantes : (1) L`appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l`appareil doit accepter tout brouillage radioélectrique subi, même si le...
  • Page 175 Transponder 7.7 SIMATIC RTLS PCB OEM AX The equipment also carries the following notes: XXXYYYZZZ [= serial number, is assigned during production] SIMATIC RTLS PCB OEM AX 7.7.1 Device description 7.7.1.1 Order data RTLS PCB OEM AX Table 7-16 Order data RTLS PCB OEM AX...
  • Page 176 Transponder 7.7 SIMATIC RTLS PCB OEM AX Description / Function Grounding Grounding P800 socket Internal interface for production and manufacturing test, do not use. P201 socket TMA connector Type: JST BM08B-SRSS-G-TBT Description / Function Not used Power In +5 V...
  • Page 177 7.7 SIMATIC RTLS PCB OEM AX 7.7.1.4 Dimension drawing The two antennas are arranged standing up on the top side of the PCB. Figure 7-7 Dimension drawing SIMATIC RTLS PCB OEM AX - All dimensions specified in millimeters 7.7.2 Installation & Operation 7.7.3 Technical specifications...
  • Page 178 Transponder 7.7 SIMATIC RTLS PCB OEM AX 6GT2700-8DF00-0AX0 Operating frequency rated value 3100 MHz … 4800 MHz 6000 MHz ... 7000 MHz Transmit power 0.037 mW (-41.3 dBm/MHz) Range Max. 30 m Accuracy of the localization 0.2 m Antennas UWB antenna integrated PHASE radio frequencies (data transfer and optional locali‐...
  • Page 179 Transponder 7.7 SIMATIC RTLS PCB OEM AX The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
  • Page 180 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM AX (MLFB 6GT2700-8DF00-0AX0); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 181 Transponder 7.7 SIMATIC RTLS PCB OEM AX Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 182 Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC.
  • Page 183 Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP Description / Function Tx - Output on transponder, 2.5 V Supply voltage, 3.3 V ±100 mV P1 connector The individual pins are connected to the solder contacts (P4). Type: JST SM04B-SRSS-TB Description / Function Rx - Input on the transponder, 2.5 V (3.3 V)
  • Page 184 Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP Figure 7-8 All dimensions specified in millimeters. Antenna Figure 7-9 All dimensions specified in millimeters. System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 185 Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP 7.8.2 Installation & Operation 7.8.3 Technical specifications Table 7-19 Technical specifications of the transponder RTLS PCB OEM CHIRP 6GT2700-8CF02 Product name SIMATIC RTLS PCB OEM CHIRP CHIRP radio frequencies (localization) Wireless method IEEE 802.15.4a nanoLOC...
  • Page 186 Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
  • Page 187 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM CHIRP (MLFB 6GT2700-8CF02); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 188 Transponder 7.8 SIMATIC RTLS PCB OEM CHIRP Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 189 Transponder 7.9 SIMATIC RTLS PCB OEM PULSE UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval. The labeling of electrical equipment is as follows: LISTED E223122 IND.CONT.EQ FOR HAZ.LOC.
  • Page 190 Transponder 7.9 SIMATIC RTLS PCB OEM PULSE Description / Function Tx - Output on the transponder, 3.3 V Supply voltage 3.3 V P1 connector The individual pins are connected to the solder contacts (P4). Type: JST SM04B-SRSS-TB Description / Function Rx - Input on the transponder, 3.3 V...
  • Page 191 Transponder 7.9 SIMATIC RTLS PCB OEM PULSE Figure 7-10 All dimensions specified in millimeters. Antenna Figure 7-11 All dimensions specified in millimeters. System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 192 Transponder 7.9 SIMATIC RTLS PCB OEM PULSE 7.9.2 Installation & Operation 7.9.3 Technical specifications Table 7-21 Technical specifications of the transponder RTLS PCB OEM PULSE 6GT2700-8AF03 Product name SIMATIC RTLS PCB OEM PULSE PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2011 UWB...
  • Page 193 Transponder 7.9 SIMATIC RTLS PCB OEM PULSE Link: (https://support.industry.siemens.com/cs/products? dtp=Certificate&mfn=ps&pnid=14970&lc=en-US) The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of...
  • Page 194 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS PCB OEM PULSE (MLFB 6GT2700-8AF03); FCC ID NXW- RF380R02 This device complies with part 15 of the FCC rules. Operation is subject to the following two...
  • Page 195 Transponder 7.9 SIMATIC RTLS PCB OEM PULSE (2) this device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
  • Page 196 Transponder 7.9 SIMATIC RTLS PCB OEM PULSE You will find the current versions of the standards in the currently valid UL HAZ. LOC. certificates. UL HAZ. LOC. identifier NOTICE Validity only when the devices are labeled Only devices with the UL HAZ. LOC. mark have the corresponding approval.
  • Page 197 Accessories System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 198 Accessories System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 199 System integration System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 200 System integration System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 201 System diagnostics System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 202 System diagnostics System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 203 Index Support, 9 Training, 9 System Manual, 04/2019, C79000-G8976-C577-01...
  • Page 204 Index System Manual, 04/2019, C79000-G8976-C577-01...

Table of Contents