Siemens RM400 C Series Operating Manual page 74

Table of Contents

Advertisement

6
Online replacement (OLR)
(3)
LEDs
green
red
flashing red
OLR must be performed by an experienced and suitably trained system adminis-
trator, and it must be carried out only if the drive configuration and the drives and
OLR shuttles being used all meet defined conditions.
Criteria to be met by the system administrator
Sound knowledge of the operating system (Reliant UNIX/SINIX V5.42)
Sound knowledge of system administration
Experience of using the graphical interface of the HW configuration tool Config
under SINIX/windows (henceforth referred to as XConfig), or
Experience of using the alphanumeric interface of Config under the SYSADM
menu item
configuration
Hard drive and configuration criteria
The 3 1
" hard disk drives must be housed in a 3 1
/2
Drive mirroring
All the hard drives in the SCSI chain must be fully mirrored by matching
hard drives in another SCSI chain (OLR group definition in the /etc/dktab
file).
All the devices in both SCSI chains must be hard disk drives, and the
drives must all be housed in a 3 1
Allocation of the two SCSI chains to the associated controllers must be
performed with XConfig or Config.
64
Disk is being accessed.
The drive must not be replaced while this LED is on.
Disabled disk.
The disk can now be replaced.
Configuration is being checked.
The drive must not be replaced when this LED is flashing.
(henceforth referred to as Config).
RM400 C Models
" OLR shuttle.
/2
" OLR shuttle.
/2
U24802-J-Z146-2-7600

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm400 c60Rm400 c62Rm400 c70Rm400 c72Rm400 c80Rm400 c90

Table of Contents