Siemens SIMATIC NET RUGGEDCOM RS900GPF Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS900GPF:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS900GPF
Edition
01/2021
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RS900GPF

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS900GPF Edition 01/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS900GPF Communication Ports Technical Specifications Installation Manual Certification 01/2021 C79000-G8976-1353-05...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Supported Fiber Optic Cables ................
  • Page 5 Table of Contents Failsafe Alarm Relay Specifications ..............23 Copper Ethernet Port Specifications ..............24 Fiber Optic Ethernet Port Specifications ............... 24 Operating Environment ..................25 Mechanical Specifications ..................25 Dimension Drawings ................... 26 Certification ......................... 31 Approvals ......................31 6.1.1 TÜV SÜD ......................
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Preface Contacting Siemens • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RS900GPF is an industrially hardened, fully managed Ethernet switch providing dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports, each capable of supplying high power 802.3at compliant Power over Ethernet (PoE). Designed to operate reliably in harsh industrial environments, the RUGGEDCOM RS900GPF provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations, factory floors or in curb side traffic control cabinets.
  • Page 11: Description

    Introduction 1.2 Description Power Supply • Single 54 VDC, 255 W (or greater) external power supply can deliver 30 W x 8 port per IEEE 802.3at • Second power supply input for a redundant 54 V power supply • Complies with IEEE 802.3af, 15 W x 8 output when using 48 VDC power supplies Description The RUGGEDCOM RS900GPF features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device.
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Color Description Green Device is receiving power No power ALARM LED Illuminates when an alarm condition exists. Failsafe Alarm Relay Latches to default state when a power disruption or other alarm condition occurs. For more information, refer to: •...
  • Page 13: Supported Fiber Optic Cables

    Introduction 1.5 Supported Fiber Optic Cables Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions. Cable Type Wavelength (nm) Modal Bandwidth Distance (m) (MHz·km) 100Base-FX 1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — — OM2 (50/125) —...
  • Page 14: Installing The Device

    Installing the Device This section describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 15: Unpacking The Device

    If any item is missing or damaged, contact Siemens for assistance. Cabling Recommendations Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 16: 2.3.1 Mounting The Device On A Din Rail

    Installing the Device 2.3.1 Mounting the Device on a DIN Rail Note For detailed dimensions of the device with either DIN rail or panel hardware installed, refer to "Dimension Drawings (Page 26)". 2.3.1 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RS900GPF can be ordered with a DIN rail adapterthat can be affixed to the back of the chassis.
  • Page 17 Installing the Device 2.3.1 Mounting the Device on a DIN Rail Hook the top teeth of the adapter onto the DIN rail. Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver. DIN Rail DIN Rail Adapter Figure 2.2 Mounting the Device to a DIN Rail...
  • Page 18: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.3 Removing the Device from a DIN Rail...
  • Page 19 Installing the Device 2.3.2 Mounting the Device to a Panel Rear Mount Orientation Front Mount Orientation Side Mount Orientation Figure 2.4 Panel Mount Options Secure the adapters to the device in the desired orientation. Place the device against (side or rear mount orientation) or insert it into (front mount orientation) the panel and align the adapters with the mounting holes.
  • Page 20: Grounding The Device

    Installing the Device 2.4 Grounding the Device Install #6 screws (not supplied) to secure the adapters to the panel. Grounding the Device The RUGGEDCOM RS900GPF chassis features a threaded hole for connecting the device to ground (Earth). It is recommended to terminate the ground connection with an M3 ring or spade lug, and then torque to 1.7 N·m (15 lbf-in).
  • Page 21: Connecting Power

    For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to https:// support.industry.siemens.com/cs/ww/en/view/109478699.
  • Page 22 Installing the Device 2.6 Connecting Power To connect a power source to the low DC power supply, do the following: Secure a European-style terminal block (or Euroblock) to one of the available terminals. Connect the positive wire from the power source to the positive terminal on the terminal block.
  • Page 23 Installing the Device 2.6 Connecting Power RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 24: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS900GPF console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RS900GPF User Guide for the RUGGEDCOM RS900GPF. Serial Console Port Connect a PC or terminal directly to the serial console port to access the boot-time control and RUGGEDCOM ROS console interface.
  • Page 25: Configuring The Device

    Device Management 3.2 Configuring the Device Name Description Reserved (Do Not Connect) Connected internally. Connected internally. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS900GPF console and Web interfaces via the device's IP address.
  • Page 26: Communication Ports

    Communication Ports The RUGGEDCOM RS900GPF features eight standard 10/100Base-TX copper RJ45 Ethernet ports capable of Power-over-Ethernet (PoE). It can also be equipped with two additional Gigabit Ethernet capable ports, for which many fiber transceiver and copper options are available. Each communication port type has a specific place in the RUGGEDCOM RS900GPF chassis.
  • Page 27 Communication Ports 4.1 Copper Ethernet Ports WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference If shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury.
  • Page 28 Communication Ports 4.1 Copper Ethernet Ports Name Description 10/100Base- 1000Base- BI_DB- Receive Data- or Bi- Directional BI_DA+ Transmit Data+ or Bi- Directional Reserved BI_DD+ (Do Not Directional Connect) Reserved BI_DD- (Do Not Directional Connect) BI_DA- Transmit Data- or Bi- Directional Reserved BI_DC+ (Do Not Directional...
  • Page 29: Poe Ports

    Communication Ports 4.2 PoE Ports PoE Ports The RUGGEDCOM RS900GPF supports eight 10/100Base-TX Power over Ethernet (POE) ports (ports 1 to 8). Each port complies with the IEEE 802.3at and IEEE 802.3af standards, and feature the ability to automatically enable/disable power when PoE- capable devices are connected or removed.
  • Page 30: Fiber Optic Ethernet Ports

    Communication Ports 4.3 Fiber Optic Ethernet Ports Pin-Out The pin-out for the PoE ports is as follows:   Name Description Receive Data+ Receive Data- Transmit Data+ Figure 4.7 RJ45 Ethernet Port Pin Configuration Transmit Data- Specifications For specifications on the available PoE ports, refer to "Copper Ethernet Port Specifications (Page 24)".
  • Page 31: Sfp Transceivers

    RUGGEDCOM SFP Transceiver Catalog [https:// installation/removal, refer to the support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RS900GPF...
  • Page 32: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Power Minimum Maximum Fuse Rating Isolation Maximum Maximum Supply Type Input Input Power Combined Consumption Power Output at PoE Ports 54 VDC 45 VDC 57 VDC 6.3A (T) 1.5 kVDC 15 W...
  • Page 33: Copper Ethernet Port Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens Sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 34: Operating Environment

    Technical Specifications 5.6 Operating Environment Mode Connector Cable Tx λ Tx min. Tx max. Distance Power Type Type (nm) (dBm) (dBm) Sensitivity Saturation (km) Budget (μm) (dBm) (dBm) (dB) 9/125 1300 9/125 1300 Typical. Gigabit Ethernet (1 Gbps) Optical Specifications Cable Power Connector Tx λ...
  • Page 35: Dimension Drawings

    Technical Specifications 5.8 Dimension Drawings Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 89.9 154.4 Figure 5.1 Overall Dimensions RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 36 Technical Specifications 5.8 Dimension Drawings 44.5 38.1 156.9 26.0 64.1 Figure 5.2 Panel Mount Dimensions (Rear Mount Shown) RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 37 Technical Specifications 5.8 Dimension Drawings 44.5 90.0 41.4 17.8 38.1 137.9   Figure 5.3 Panel Mount Dimensions (Side Mount Shown) RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 38 Technical Specifications 5.8 Dimension Drawings 174.2 163.1 175.8 Figure 5.4 DIN Rail Mount Dimensions RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 39 Technical Specifications 5.8 Dimension Drawings RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 40: Certification

    UL 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements) 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment –...
  • Page 41: 6.1.3 Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 42: Iso

    Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 43 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels DC Power ± 1.5 kV Ports Earth ± 2 kV Ground Ports Surge Signal Ports ± 500 V Line-to-Earth 61000-4-5 ± 500 V Line-to-Line DC Power ± 500 V Line-to-Earth Ports ±...
  • Page 44 Certification 6.2 EMC and Environmental Type Tests temporary communication loss, while Class 2 requires error-free and interrupted communications. Description Test Levels Enclosure Contact ± 8 kV Enclosure Air ± 15 kV Radiated RFI Enclosure Ports 35 V/m Fast Transient Signal Ports ±...
  • Page 45 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RS900GPF Installation Manual, 01/2021, C79000-G8976-1353-05...
  • Page 46 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents