To initiate replacement you successively select the following menu items,
confirming each selection with Ú:
configuration – load – storage devices – disk<s>
Then use the [ACTIONS] key to select operation->Replace disk xxxx online.
Ê
Config checks that all the conditions are met, suspends mirroring for the defective
drive and disables the drive. A message on the screen indicates where the drive is
located on your system. Then the query Exchanging disk done? is displayed. If the red
LED on the defective drive is on, you can remove the drive and install the
replacement.
Using the RAIDmaster Storage Manager to identify a defective drive
If you have a RAID setup, you can identify a defective hard drive with the aid of the
RAIDmaster Storage Manager. Also refer to the "RAIDmaster - System Adminis-
trator's Guide".