Toshiba STRATA DK24 Manual page 99

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

INSTALLATION-CONFIGURATION
SECTION 200-096-204
FEBRUARY1991
telephones).
Each DDSS console does not require
a specialized
interface
PCB; instead,
each DDSS
console takes the place of one digital telephone
on
a PDKU PCB. However,
only one DDSS console
may be interfaced
to a PDKU, and it must interface
to circuit 8. Likewise,
each DSS console
does not
require a specialized
interface
PCB; instead,
each
DSS console
takes
the place
of two electronic
telephones
on a PEKU PCB. However,
only one
DSS console
may be interfaced
to a PEKU, and it
must interface
to circuits 7 and 8. Table 4-E pro-
vides more details regarding
DDSS and DSS con-
soles.
Example
4-An
end user requires
nine CO lines,
15 electronic
telephones,
one DSS console
and
external
paging.
l
If external
paging
speakers
can be driven
with 3 watts or less, then the PEPU PCB can
be employed
as the paging
amplifier.
Since
each DSS console
requires the equivalent
of
two electronic
telephones
for interface,
a
total of 17 equivalent
electronic
telephones
must
be interfaced
and,
therefore,
three
PEKU PCBs are needed.
Aside from com-
mon equipment,
the PCBs required
for this
configuration
are as follows:
Three PCOU PCBs
Three PEKU PCBs
One PEPU PCB
l
A total of seven
universal
slots are needed
(which is within the maximum
of DK56's eight
universal
slots).
Example
5-A
mid-sized
business
needs
15 CO
1
lines, 12 digital telephones,
two DDSS consoles,
14 electronic
telephones,
two DSS consoles,
external
paging
system
interface
to drive
an
existing 8-ohm
speaker,
and SMDR.
l
Because
SMDR is a requirement,
the PIOU
amplified
page output
and SMDR
interface
will be needed.
This unit can also handle the
external
paging
system
interface
require-
ment.
Two
DDSS
consoles
require
the
equivalent
of two digital telephone
circuits in
addition
to the 12 digital telephones,
for a
total
of 14 digital
telephone
circuits;
this
results in the installation
of two PDKU PCBs.
Two DSS consoles
require the equivalent
of
four electronic
telephones,
for a total of 18
electronic
telephone
circuits; this results in
the installation
of three
PEKU PCBs. The
-
final PCB configuration
(in addition
to corn-
.j
mon equipment)
is:
Four PCOU PCBs
Three
PEKU PCBs
Two PDKU PCBs
I
One PIOU PCB
l
The total universal
slots needed
equals
10,
so that a DK96 would
be sold to this busi-
ness.
2.20 Data Interface Units (PDIU-DI and PDIU-DS)
2.21 Integrated Data Interface Unit (PDIU-DI):
Digital telephones
may be equipped
with a PDIU-
DI. The PDIU-DI
is not astand-alone
unit, and must
be attached
to a digital telephone.
Each system can
support
amaximum
numberof
PDIU-Dls,
asshown
in Table 4-B. The PDIU-DI and the digital telephone
it is integrated
into share the same circuit on the
PDKU PCB.
2.22 Stand-alone Data Interface Unit (PDIU-DS):
Each PDIU-DS
requires
one circuit on a PDKU
PCB. A PDIU-DS
can be connected
to any circuit
on a PDKU,
and as many as eight can be con-
nected to a PDKU. Unlike the PDIU-DI,
the PDIU-
DS does not share a circuit with a digital telephone.
Therefore,
each PDIU-DS
reduces
the digital tele-
phone maximum
capacity
by one. Each system can
suppot-tamaximumnumberofPDIU-DSs,asshown
in Table 4-B.
NOTE:
1. The PDIU-DI
and PDIU-DS
will function
with all slots, except slots 11 - 14 in DK96.
2. PDKU circuits 1 - 7 can support
PDIU-Dls
and PDIU-DSs.
Example
6-A
small law firm requires
three CO
lines, IO digital telephones
(all of which will be
equipped
with a PDIU-DI
connected
to a per-
sonal computer)
and two PDIU-DSs
connected
to modems.
l
The telephones
will require IO PDKU circuits
and the modem/PDIU-DSs
two more. The
PDIU-Dls
do not require
a dedicated
circuit,
because
they share one with the digital tele-
phones
to which they are connected.
A total
of 12 digital
circuits
are required
for this
configuration;
therefore,
two PDKUs would
4-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents