Toshiba STRATA DK24 Manual page 286

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

PROGRAMMINGPROCEDURES-INTRODUCTION
SECTION 200-096-301
FEBRUARY1991
TABLE I-B (continued)
MULTIDIMENSIONALPROGRAM: PROGRAM30,
STATION CLASSOFSERVICE
Press...
Step
m
+ LED keys
#
Action description
LCD RESPONSE . . .
6.
LED keys 01 - 20 (continued)
LED 12 and 13:
Digital Telephone
Handset
Receiver
Volume (Release 3).
LED 14:
Account
Codes Verified (Release 3).
LED 15:
Verified Account
Code Revision
Authority
(Release 3)
LED 16:
Traveling
Class of Service Code Revision
Authority
(Release 3).
LED 17:
Do Not Disturb Override Allowed.
LED 18:
Executive
Override
Allowed.
LED 19:
Privacy Overrided
Allowed
LED 20:
Not Used
If programming
a port range, the LED indications
are
as follows:
l
LED-ON, all ports in range are enabled
for that
item.
l
LED-OFF, all ports in range are disabled
for that
item.
l
LED-FLASHING,
some ports in range are enabled
and some ports are disabled.
7.
m
Secure data in system programming.
8.
m
Prepare system for another selection (go back to
step 5), or exit Program 30 (continue with step 9).
30 SELECT = (00 -, 95)
DATA PROGRAMMED
30 SELECT =
9.
iim
Secure Program 30 data in system memory.
10.
m
Exit Program 30. Enter another program number (see
Table Q), or exit programming
mode (go to step 11).
System beeps to indicate it is exiting Program 30.
11.
[[m
Exit programming
mode.
30 SELECT = ##
DATA PROGRAMMED
PROGRAM =
NO.
205
JAN
20
SUN
06:58
1-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96