Toshiba STRATA DK24 Manual page 114

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

INSTALLATION-CONFIGURATION
SECTION 200-096-204
FEBRUARY1991
Vinted
Circuits per
Zircuit
Printed
Board
Circuit Board
PCB Maximum Capacities
(Ports/Lines)
DK24
DK56
DK96
PCTUSl
PCTU
PCTU
PCTU
(l/2/3)
(l/2/3)
(l/2/3)
Interface to:
0
I
PDKU
8/Digital
Telephone
=W=
(POETS,
Digital)
JCTU3)
(without
PDIU-DI)
(with PDIU-DI)
8/Electronic
Telephone
PEKU '
(Ports,
Electronic)
3
4
8
12
* Digital Telephones
- DSS Consoles
(24)
(32)
(64)
(96)
* PDIU-DI
(N/A)
(32)
(64)
(96)
* PDIU-DS
(N/A)
(21 j5
(53?
W5
3
4
8
12
* Electronic
Telephones
* HDCB
Door Phone
Box
* DSS Consoles
(24)
(32)
(64)
(96)
* BGM
Source
* EOCU
PCB for OCA
* Amplified
Conference
* Standard
Telephones
(r
PC
i
PSTU
8/Standard
Telephone
3
4
7
12
* Voice
Mail Ports
* FAX
(Ports,
Standard)
(24)
(32)
(56)
(96)
* Dictation
Machine
* Off-premises
Stations
* Other
similar
devices
PESU 2
2/Standard
Telephone
equires
4/Electronic
Telephone
3
5
8
12
Standard:
Same
as PSTU
'TU2
and
(Ports
Standard/
shove)
Electronic)
(6/12)
(1 O/20)
(16/32)
(24/48)
;~~t;&~ame
as PEKU
4/CO
Lines
4
5
7
PCOU
9
* Central
Office
(Lines)
(16)
(20)
(28)
(36)
Loop-Start
Lines
PEMU 3
4/TIE
Lines
1
1
2
3
* E&M TIE Lines
- Type
I - Signaling
(Lines)
(4)
(4)
(8)
(12)
- 2 or 4 wire transmission
-
Immediate
start
I
C
PIOU,
PIOUS
See Table
4-F
1
1
1
1
See Table
4-F
)r PEPU
NOTES:
TABLE4-C
UNIVERSAL SLOT/PCB CAPACITIES
1. The appropriate
capacities
apply to 1 OOO-series digital and 6500-series
electronic
telephones
only.
if other Toshiba
electronic
telephones
(2000-,
3000-,
6000-) are used, refer to Paragraph
1.12.
2. The PESU provides
two standard
telephone
circuits identical
to PSTU circuits and four electronic
telephone
circuits identical
to PEKU circuits. Normally
only one PESU is installed in a system that
requires a mix of standard
and electronic
telephone
circuits. A PESU is installed instead ofa PSTU,
if only one or two standard
telephone
circuits are needed.
A PESU is installed
instead
of a PEKU
if only four or less electronic
telephone
circuits are needed,
The PESU supports
the door phone
option and the BGM source but not DSS consoles.
3. The maximum
number
of PEMU
PCBs is determined
by the system's
power
supply
capability
(caution:
do not exceed
the numbers
shown);
also; if a PEMU is installed in a DK24 with a PCTUS
PCB, only 16 station ports are available
for telephones.
4. Only one type of peripheral
interface
PCB (PiOU, PIOUS,
PEPU) may be installed
per system.
5. The number
of digital telephones
with PDIU-Dis
is limited by the system's
power
capacity
per
Worksheet
7. Also, PDIU-Dis
are limited to slots 01 N 10 in DK96 (see Table 4-B for details).
4-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents