Toshiba STRATA DK24 Manual page 317

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS
SECTION 200-096-302
FEBRUARY1991
Restriction
Class
can be assigned
with
Program
70 to each of the 300 Verified
Account
Codes.
l
Verified
Account
Code
Dial
Require-
ment (Release
3)-Verified
Account Code
Dial Requirement
is assigned
on a station-
by-station
basis in Program
30, LED 140N.
All Account
Codes dialed (forced or volun-
tary) from stations
assigned
in this pro-
gram will be verified.
l
Code Change-Stations
selected
in Pro-
gram 30, LED 15 ON, can change
Verified
Account
Codes
(VAC)
by dialing
the
following:
~+~~~+ono-ooo+VAC+~or~
l
Verified
Account
Codes:
Forced/Volun-
tary Program
Options
(Release
3)-Any
station can dial a Voluntary
Account
Code
after accessing
a CO line ( 0
F
11;
or,
with Release
3, dial 1 1 @ or press the
B
button).
Forced Account
Code
requirements
are assigned
via station and
CO line program
options:
stations
are as-
signed
in Program
30, LED 08 ON; and
CO lines are assigned
in Program
15-7.
Stations
must dial Verified Account
Codes
when assigned
in Program
30, LED 14 ON.
Program
70-Verified
Account
Code
Toll Re-
striction
Assignments
(Release
3): A Toll
Restriction
Class can be assigned
with this
program
to each of the 300 Verified
Account
Codes
assigned
in Program
69. Therefore,
when a Forced Verified Account
Code is dialed
at a station,
the station
temporarily
assumes
the toll restriction
class assigned
to the Verified
Account
Code.
When
Program
70 is initial-
ized, all Verified Account
Codes are assigned
as not toll restricted
(data = 00). Verified
Ac-
count Code Toll Restriction
class assignments
are not user programmable;
so if the assign-
ments
are not known,
it is recommended
to
assign
a number
(block) of Verified
Account
Codes to each type of toll restriction
class. For
example:
VACs 000 - 050 = no restriction
VACs 051 - 100 = total restriction
VACs 101 - 150 = Class 1
etc.
Program
77-I-Peripheral
Options:
l
Door LockTime,
LED 20-The
Door Lock
relay contact may be programmed
to'oper-
ate for either 3 or 6 seconds
(applies
to
PIOU, PIOUS, PEPU, and HDCB door lock
controls).
l
PEKU
Port Number/HDCB,
LEDs
16 -
1 g--Door
phone/lock
existence
is defined
by this program.
Door phone/lock
control-
lers (HDCB) can only exist at ports 04, 12,
20 and 28, and can only be installed on the
5th circuit of a PEKU and/or
PESU. After
assignment
of an HDCB, door phone num-
bers (151 - 159, 161 - 163) will effectively
replace
the station
number
assignment
in
Program
04. The door lock option is set via
Program
77-2.
NOTE:
HDCB4,
port28,
is not available
with PCTUS.
l
IMDU Modem,
LED 14-Informs
the soft-
ware that an internal Remote
Maintenance
modem
(IMDU)
is installed.
Its station
number
is 19 (unless
the access
code
prefix has been changed
with Program05).
l
Night Ringing
over External
PageZones,
LEDs 10 - 13 (Release
3): For each ex-
ternal paging
zone, Tenant
1 or Tenant
2
CO lines can be selected
with this program
to night ring. For this feature
to work, the
appropriate
CO lines must be programmed
to night ring overexternal
page in Program
78. Tenant
assignments
are
made
in
Program
15.
NOTE:
The PIOU option
PCB must be installed
to
allow this option.
l
Door
Phone
Ring
On External
Page,
LED08-If
adoor phone button is pressed,
a ring tone can be enabled
or disabled
to
external
paging when the system is in night
mode.
Activation
of a m
button
is re-
quired
to activate
this feature.
The m
does not apply to door phones.
l
Door
Lock
Relay/External
Page Relay,
LED 07-A
relay on the PIOU, PIOUS or
2-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents