Toshiba STRATA DK24 Manual page 96

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

INSTALLATION-CONFIGURATION
SECTION 200-096-204
FEBRUARY 1991
I
1 INTRODUCTION
1.01 STRATA
DK systems
are flexible
in their
ability to meet varied
system
needs.
A modular
building block approach
allows the addition
of vari-
ous parts to meet system
needs and applications.
A universal
slot concept
is used in the KSU, which
means that a PCB slot in the KSU can accept any
one of a number
of different
PCBs. This is con-
trasted
with a dedicated
slot approach
(used
in
previous
STRATA systems),
where a particular
slot
can only accept a specific PCB, such as a CO line
interface
PCB. DK24 has six universal
slots, DK56
has eight, and DK96 has 14. This increased
flexibil-
ity in STRATA
DK means
that tradeoffs
can be
made between
the number of CO lines and stations
in a system application.
This is illustrated
in Figure
4-1.
1.02
Figure 4-l shows that in most configurations,
four CO lines can be traded
for eight
stations.
Conversely,
for every eight stations
that are given
up, four CO lines can be added.
The maximum
quantities
of 16 CO lines for DK24,20
CO lines for
DK56,
and 36 CO lines for DK96
are based
on
squared
systems.
Software
allows 16 CG lines with
PCTUSl
and 36 CO lines with PCTU (1, 2, or 3). 1
Similarly,
the 24 station
(PCTUSI)
and 96 station
(PCTUI,
2, or 3) limits are software
limitations.
I
1.10 System
Considerations
1.11 When
no external
options
or TIE lines are
installed
and only CO lines and station
PCBs are
exchanged,
the maximum
configurations
can be
summarized
in Table 4-A.
1.12 Table
4-A shows
the maximum
number
of
1 OOO-series digital
telephone,
6500-series
tele-
phones,
and/or standard
telephones
that can exist
in each
system.
Due to power
availability,
the
numbers
decrease
if using 2000-, 3000-,
6000-, or
6005-series
electronic
telephones,
a PEMU PCB,
or digital
telephones
with
PDIU-Dls
connected.
I
When mixing different
series telephones
and/or if a
PEMU
PCB is installed,
use the Configuration
Guide,
worksheet
7, to verify that the power sup-
plied is greater
than the power
used.
40
36
32
28
24
AVAILABLE
CO LINES
20
16
12
8
4
NOTES (DK24):
1. 24 stations are available
0
with PCTUSl -equipped
DK24.
2. 32 stations are available
with PCTU-(1, 2, or 3) equipped
(WITHOUT
SYSTEM OPTIONS)
AVAILABLE
STATION PORTS
DK24.
I
-_-__--
- .
---
--~~~
FIGURE 4-l-PCB
CONFIGURATION CHART
4-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents