Toshiba STRATA DK24 Manual page 194

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

7.03 System Program Data Printout.
If a printer
is connected
to the SMDR port, customer
program
information
stored
in the PCTU or PCTUSI
RAM
may be printed out for reference
by using
Program
97 (see Paragraph
7.14).
7.10 SMDR Hardware Requirements
7.11
A DK system
must be equipped
with a PIOU
or PIOUS
PC6 to support
the SMDR
printer/call
accounting
device option. Connection
of the printer
or call accounting
device to the PIOU or PIOUS
PCB is accomplished
with a 3-pair modular
cord (7
feet maximum)
and a PPTC connector
adaptor
(refer to Figure 8-19 for details).
Call record data is
ASCII-formatted,
8 bits, no parity, 1 -stop bit.
7.12 The PIOU or PIOUS contains
a call record
buffer which stores call record data (for up to 50
calls) when the printed or call accounting
device is
turned
off, or when
no device
is connected
to the
SMDR port. No further call records are stored after
the buffer is filled. When the printer or call account-
ing device
is made
operational,
an "ERROR
BUFFER
OVERFLOW"
message
is printed to indi-
cate that the buffer
was full, and that some
call
information
may have been lost.
7.13 SMDR Programming Considerations
7.14 SelectableprogrammingoptionsfortheSMDR
printer or call accounting
device are:
Program 60
l
Item 3-Selects
the records of outgoing
calls or
outgoing
and incoming
calls to be printed.
l
Item 4-Selects
digit length of account code (4 to
15 digits).
l
Item 5-Allows
only long distance
call records to
be printed.
Program 97
l
Allows system program
data to be printed via the
SMDR port (refer to Figure 8-20 for an example
printout).
NOTES:
1. An SMDR
printer
must be connected
to
the SMDR port to use the printout
option
selected
by Program
97.
2. Call record data is lost when program
data
is printed
out using
Program 97.
INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY 1991
7.20 SMDR Printer/Call Accounting Device In-
stallation
7.21
Install the SMDR
printer/call
accounting
de-
vice option in accordance
with the following
steps
(refer to Figures 8-19, 9-l 7, and 9-l 9):
1)
2)
3)
4)
Connect
the interface
cable
and the PPTC
adaptor
from the PIOU or PIOUS SMDR port
to the SMDR printer or call accounting
device
DB25 connector.
Set the PIOU or PIOUS
SW1
switch
to the
appropriate
baud rate (300 or 1200 bps), as
determined
by the baud rate of the printer or
call accounting
device.
Set the printer or call accounting
device to 8-
bits/no
parity/one
stop bit.
Program
(Program 60)
the system for the re-
quired
SMDR
printer/call
accounting
device
options
(refer to Paragraph
7.13 and the Pro-
gramming
Procedures,
Section 200-096-300).
8 MAINTENANCE
TERMINAL
OPTIONS
8.00
A customer-supplied
maintenance
terminal
may be connected
to the system
(PIOU or PIOUS)
either locally or remotely.
The maintenance
termi-
nal (ASCII terminal)
allows system
programming
and testing
to be accomplished.
Also, the IMDU
modem or an external maintenance
modem (300 or
1200 baud full-duplex)
can be connected
to allow
system
programming
and testing
to be accom-
plished from a remote
location.
NOTE:
An external
modem
is required
for Remote
Maintenance
if an IMDU is not installed
on the
PIOU
or PIOUS.
The IMDU
has a built-in
maintenance
channel
for remote
connection;
however,
an external
modem
requires
a CO
line, PSTU or PESU port.
8.10 Maintenance Terminal/External
Modem
Option System Hardware Requirements
8.11
The STRATA
DK system
must be equipped
with a PIOU or PIOUS PCB to support
the mainte-
nance terminal/external
modem
options.
Connect-
ing the maintenance
terminal
or external
mainte-
8-13