INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY1991
STRATA DK (Release 3)
nnne
I
RS-
RS-
FlGURE8-36-PCTO
PRINTERTESTCALL USING MANUAL DIALING
l
PC 1 and PC 2 screens both display,
NO CARRIER.
l
The Data LEDs on each DKT are off.
12.83
PC to Printer
Test
Call
Using
Manual
Dialing
(see Figure
8-36)
1) DIU Programming:
l
Program
20: Port 01. LEDs 01, 02, and
17 ON; all other LEDs OFF.
l
Program
20: Port 03. LEDs 01,04,
and
17 ON; all other LEDs OFF.
l
Program
39: Port 01. m
(56) and
m
(54) buttons
should be provided.
l
Default settings for PDIU-DI, S-Registers.
2) Make sure the PC is configured
to print data
from its serial COM port (the PC COM port
connected
to DKT/PDIU-DI
port 01). This is
normally
accomplished
using the DOS and
MODE commands.
3) Using
the
manufacturer's
documentation,
make
sure the communication
parameters
(data speed, parity, data bits, stop bits, etc.) of
the PC COM port match
the printer's
serial
interface
parameters.
4) To connect
the PC to the printer,
press the
DKT's m
button and dial 111
.
l
The CONNECT
on the PDIU-DS
will be
lit.
l
The connection
between
the PC and the
printer
is completed,
as shown
by the
thick lines above (PDIU-DS
203 is in the
communication
mode).
l
If busy tone
is sent to the
DKT, the
connection
is not complete;
press m
and try step 4 again.
5) Operate
the PC to print data as required.
6) To terminate
the call, press the DKT's m
button.
I
8-56