Toshiba STRATA DK24 Manual page 119

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

INSTALLATION-CONFIGURATION
SECTlON200-096-204
FEBRUARY1991
NOTE:
The above
also applies
when
the EOCU
is
installed
on a PEW
PCB.
l
DSS: If a PEKU is required
to support
a DSS
console,
record
DSSl,
DSS2,
DSS3,
and/or
DSS4, as needed,
under the appropriate
PEKU
slots. Start with DSSl
in the lowest
DSS-sup-
porting
PEKU slot, and continue,
as required,
to
DSS4 in the highest
PEKU slot that is to support
a DSS console.
A special PCB code is required
for PEKU PCBs that support
the DSS console
option (refer to DSS console
hardware
configu-
ration notes at the end of this section).
I
NOTE:
The above
also applies
when
connecting
DDSSs
to PDKU PCBs.
l
HDCB:
If a PEKU is required
to support a door
phone control box, record HDCB 04, HDCB 12,
HDCB 20, and HDCB 28 under the appropriate
PEKU slots. Start with HDCB 04 in the first PEKU
slot, and continue without skipping a PEKU slot, as
required,
to HDCB 28 in the fourth PEKU slot. A
special PCB code is not required for PEKU PCBs
that support the HDCB option (refer to door phone
hardware
configuration
notes at the end of this
section).
NOTE:
The above also applies when HDCBs are con-
nected to PEW PCBs.
l
IMDU:
If the PIOU is to be equipped with a remote
maintenance
modem, record IMDU underthe
PIOU
slot. A special PCB code is not required for PIOU
PCBs that support the IMDU option.
NOTE:
The above also applies when the IMDU is installed
on a PIOUS PCB.
I
l
PDIU-DS:
If one or more PDIU-DS is connected
to
a PDKU, record the port it interfaces with under the
appropriate
PDKU slot. A special PCB code is not
required for PDKUs that support PDIU-DSs.
l
PDIU-DI:
If a PDIU-DI
is connected
to a digital
:.,
telephone,
the PDIU-DI and the digital telephone
1'
will share the same PDKU station port. A special
PCB code in Program
03 is not required for PDKU
PCBs that support digital telephones
with PDIU-
Dls.
I
4.15
PCB Code
Assignments-Each
PCB type
has an identification
code that must be entered
in
Program
03. If the PCB supports
an option,
a
special
PCB code
may have
to be entered
to
identify the PCB plus the option.
Record the appro-
priate
PCB code
in the PCB code
row of the
Program
03 record sheet. Use the sequential
order
shown
below:
l
PCTU (1,2,3,
or S): Assign the appropriate
PCB
I
code (91, 92, or 93) to the PCTU slot:
l
PCB Code 91: PCTU without
CRCU
l
PCB Code 92: PCTU with CRCU-4
l
PCB Code 93: PCTU with CRCU-8
l
PDKU: Assign the appropriate
PCB code (62 or
64) to all PDKU slots:
l
PCB Code 62: PDKU without
DDSS
l
PCB Code 64: PDKU with DDSS
l
PEKU:
Assign
the appropriate
PCB code (21,
22, 23, or 24) to all PEKU slots:
l
PCB Code 21: PEKU without
options
l
PCB Code 22: PEKU with EOCU
l
PCB Code 23: PEKU with DSS
l
PCB Code 24: PEKU with DSS and EOCU
l
PSTU: Assign PCB code 31 to all PSTU slots.
l
PESU: Assign appropriate
PCB code (25 or 26)
to all PESU slots:
l
PCB Code 25: PESU without
EOCU
l
PCB Code 26: PESU with EOCU
NOTE:
A special code is not required
for the HDCB if
connected
to a
PEKU
or
PESU.
l
PCOU: Assign PCB code 11 to all PCOU slots.
l
PEMU: Assign
PCB code 13 to all PEMU slots.
l
PIOU/PIOUS/PEPU:
Assign PCB code 41 to the
PIOU, PIOUS, or PEPU slot.
NOTE:
A special code is not reqbired
for-the IMDU if
equipped
on the PIOU or PIOUS.
4-24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96