1 GENERAL
1.00
This chapter
defines
the installation
site re-
quirements
necessary
to ensure a proper operat-
ing environment
for STRATA
DK systems.
Also
included
are input power
requirements,
site con-
siderations,
cable lengths/network
requirements,
and grounding
requirements.
2 INPUT POWER REQUIREMENTS
2.00
The systems
require an input power source
of 117VAC
nominal
(85VAC N 135VAC),
50/60 Hz,
15 amps.
The AC outlet
must
be dedicated
to
system
use, fused,
and grounded
(refer to Para-
graph 5).
2.01 To avoid accidental
power turn-off, it is recom-
mended that an ON/OFF wall switch not be used on
this dedicated
AC circuit.
2.02
A reserve
power
source
(two
customer-
supplied
l2-volt
batteries)
may be connected
to
the system to serve as a power failure backup.
3 SITE CONSIDERATIONS
3.00 Clearance and Location Requirements
3.01
The KSU may be table-top
or wall mounted.
Figure 3-l (DK24/56)
and Figure 3-2 (DK96) show
the minimum
clearance
requirements
for both
mounting
options.
TOP VIEW
DK24/56 UNIT
'f"
-
I 6"
b
I
I
d
2"
-
I
I
I
I
I
I
I
I
I
I
I
I
I
2" I+
I
I
I
I
I
I
I
I
I
I
I
FRONT
WORK
SPACE
APPROXIMATELY
36"
t
I
FIGURE 3-l-DK24/56
MINIMUM
CLEARANCE REQUIREMENTS
INSTALLATION-SITE REQUIREMENTS
SECTION 200-096-203
FEBRUARY 1991
TOP VIEW
l/2"
DK96 UNIT
J
FRONT
WORK
SPACE
APPROXIMATELY
36"
+
I-ItilJKt 3-Z-UK96 MINIMUM
CLEARANCE REQUIREMENTS
3.02 The following
conditions
must be considered
when selecting
a location for the KSU:
The location
MUST BE:
l
Dry and clean
l
Well ventilated
l
Well illuminated
l
Easily accessible
The location
MUST NOT BE:
l
Subject to extreme
heat or cold
l
Subject
to corrosive
fumes,
dust, or other air-
borne contaminants
l
Subject to excessive
vibration
l
Next to television,
radio, office automation,
or
high frequency
equipment
NOTE:
See Paragraph
6 for more site considera-
tions.
I
3.03
If reserve power is to be installed,
the batter-
ies will require
a well-ventilated
location
close
(within nine feet) to the KSU (the Toshiba-supplied
battery
cable is 9 feet in length).
3.10 Electrical/Environmental
Requirements
and Characteristics
3.11
The electrical/environmental
requirements
and characteristics
for each system
are provided
in Table 3C.