Toshiba STRATA DK24 Manual page 318

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

PROGRAMMINGPROCEDURES-INSTRUCTIONWSYSTEMRECORDS
SECTION 200-096-302
FEBRUARY1991
PEPU can be assigned
to operate
with the
Door Lock function
or with External
Page
for mute control.
The door lock button
is
assigned
in
Program 39;
the door
lock
activation
time
is assigned
in
Program
77-1.
This door lock function
is not associ-
ated with the HDCB
door
lock; it is an
addition
to HDCB door locks.
l
NT Relay, LED
06-A
relay, located on the
PIOU, PIOUS or PEPU, can be assigned
to
operate
in one of two Night Transfer
modes
(see next item,
MOH/NT
Relay).
In one
mode, the relay will activate
for 1 second,
and then be idle for 3 seconds
when a CO
line rings (incoming),
and the system
is in
the night mode. The intended
application
is
to control
an external
ringing
device
at
night.
Program 78
must have Ring Over
External
Page activated
for this feature.
In
the second
mode,
the relay will operate
continuously
after
Night
Transfer
(m
m)
has been activated.
One application
is for control
of an external
answering
machine.
l
MOH/NT Relay, LED
05-A
relay, located
on the PIOU,
PIOUS
or PEPU,
can be
assigned
to operate
in one of two applica-
tions. A choice must be made between
use
for Night Transfer application
(see NT Relay
above)
or Music-on-Hold
(MOH).
If used
for MOH, the relay will activate
when any
CO line or station
is placed
on hold. The
intended
application
is to control
a tape
player which is used as a Music-on-Hold
source.
called
door phone
does
not exist. Door
phones
1 A, 1 B, 1 C are numbered
151,
..
-3,
152, 153, respectively,
and are connected
."
to the HDCB at port 04. Door phones
2A,
2B, 2C are numbered
154, 155, 156, re-
spectively,
and are connected
to the HDCB
at port 12, etc.
l
Each HDCB B-jack output can be config-
ured
as a door
lock control.
Door
lock
control
buttons
for HDCB
door locks are
assigned
to electronic
or digital telephones
in
Program
39. Door lock activation
time is
1
set in
Program 77-l.
A maximum
of four
HDCB door lock controls are available
with
a PCTU
PCB; three are provided
with a
PCTUS
PCB. Each HDCB
requires
one
PEKU or PESU electronic
telephone
port.
These door locks are not associated
with,
but are
in addition
to, the
door
lock
provided
by
the
PIOU,
PIOUS,
or
PEPU PCBs. HDCB door lock control
is
available
with
Release
2 and above
soft-
ware only.
Program 78-CO Line Special Ringing Assign-
ments:
l
Ring Over External Page During Night
Mode, Feature
I-This
program
selects
which
CO lines will activate
ringing
over
external
paging facilities during the NT1 or
NT2 modes.
The NT Relay will also be
activated
if it is in the
l-second
on/
3-seconds
off mode.
Program 77-2-Door
Phone and Door Lock
Busy Assignments:
l
Each door phone
controller
(HDCB)
can
interface
with up to three door phones.
The
system
treats
each
HDCB
as a station.
Therefore,
this is quite different
from all
other station arrangements
using electronic
telephones
or standard
telephone
devices.
The system
does not automatically
know
how many door phones
are connected
to
each HDCB, so it must be told. This pro-
gram is used to enter that information
so
that a caller will receive fast busy tone if the
l
DISA/DISC CO Line Assignment,
Fea-
ture
2-This
program
assigns CO lines to
be used
with the
Direct
Inward
Station
Calling (DISC) and the Direct Inward Sys-
tem Access (DISA)features
(Release2and
above).
These
CO lines may be set for
DISCDISA
operation
during the different
system modes of DAY, DAY2 and NIGHT.
A CO line will switch to normal ringing after
ten seconds
if the outside
caller does not
use
the
DISA/DISC
feature.
Normal
function
of these lines occurs for outgoing
calls. DISA, which allows outgoing
CO line
access
and
internal
station
calling,
is
available
with
Rel6ase
2 and above
soft-
'-
ware only.
2-18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents