Toshiba STRATA DK24 Manual page 120

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

4.16 Station Port Assignments-Station
ports are
provided
by the PDKU, PEKU, PSTU, and PESU
I PCBs. Each PDKU, PEKU, or PSTU PCB provides
eight station
ports. The PESU provides
six func-
tioning
station
ports, although
it is allocated
eight
(see Paragraph
2.60).
Each PEMU uses four or
eight station ports to support
TIE lines. Each of the
PCBs must have station
port numbers
assigned.
Record the station port numbers
in the station port
numbers
row on
Program
03's record sheet. Record
m information
for each slot equipped
with a PDKU,
PEKU, PSTU, PESU, or PEMU PCB in the order
shown
below:
1
l
PDKU and/or PEKU station ports:
Assign
station port numbers,
starting with ports 00 N 07
under
slot 01,
advancing
incrementally
at eight
1
port numbers
per PDKU and/or
PEKU slot. As-
sign the numbers
in numerical
order until station
I
ports are assigned
to all PDKU and/or
PEKU
slots.
l
PSTU station ports:
Assign station
port num-
bers, starting where the last station port number
stopped,
advancing
incrementally
at eight port
numbers
per PSTU slot. Assign the numbers
in
numerical
order until station ports are assigned
to all PSTU slots.
l
PESU station ports:
Assign station
port num-
bers, starting where the last station port number
stopped,
advancing
incrementally
at eight port
numbers
per PESU slot. Assign the numbers
in
numerical
order until station ports are assigned
to all PESU slots.
NOTE:
PEW
circuits 1 and 2 are standard
telephone
ports; 3 and 4 are not used but allocated
to the
PEW
slot, and circuits 5 - 8 are electronic
telephone
ports.
l
PEMU station ports:
Assign station
port num-
bers, starting where the last station port number
stopped,
advancing
incrementally
at four port
numbers
per PEMU slot. Assign the numbers
in
numerical
order until station ports are assigned
to all PEMU slots.
NOTE:
If a PEMU is installed in a PCTUS 1 -controlled
DK24, only 16stationports
willbe available
for
INSTALLATION-CONFIGURATION
SECTION 200-096-204
FEBRUARY1991
station interface
using PDKU, PEKU, PESU,
1
and PSTU PCBs. If it is installed in a PCTU (I,
2, or 3)-controlled
DK24,
24 stations
will be
I
available,
because
of power supply capacity.
4.17 CO Line Number Assignments-Line
cir-
cuits are provided
by the PCOU and PEMU PCBs.
Each PCOU provides
four line circuits for CO loop
start line connections,
and each PEMU
provides
four line circuits to support
TIE lines (each of the
PCBs must have line numbers
assigned).
Record
CO line numbers
in the CO/TIE
line numbers
row
on
Program
03's record sheet. Record information
for each slot equipped
with a PCOU or PEMU in the
order shown
below:
l
PCOU line numbers:
Assign CO line numbers,
starting with lines01
N 04 in the lowest numbered
PCOU slot, advancing
incrementally
at four line
numbers
per PCOU slot. Assign the numbers
in
numerical
order until CO lines are assigned
to all
PCOU slots.
l
PEMU line numbers:
Assign TIE line numbers,
starting
with the next line above
the highest
PCOU line, advancing
incrementally
at four line
numbers
per PEMU slot.
4.18 PCB Additions-To
add PCBs to an existing
installation,
assign the PCBs in the order described
above.
Start with the lowest numbered
empty slot
and continue
without
skipping
a slot until all PCBs
are assigned.
Then, using the guidelines
described
above, record the new PCB configuration
informa-
tion on the record sheet for
Program 03.
NOTE:
PEMU PCBs should be first moved
to higher
slot numbers
to create the necessary
number
of empty slots for additions.
Be sure to repro-
gram for the new PEMU positions,
including
new
station
number
assignments
for the
PEMU(s).
4.20 Door Phone Hardware Configuration Notes
l
A maximum
of 12 door phones
are allowed
per
system
with PCTU
(1, 2, or 3) and nine with
PCTUSI.
Each door phone
must be connected
to an HDCB.
l
A maximum
of three door phones
may be con-
4-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents