STRATA DK FAULT FINDING
SECTION 200-096-500
FEBRUARY 1991
3.05
The flowcharts
are sequentially
arranged
to
permit rapid fault localization
within the system.
All
fault clearing must begin with the Fault Classifica-
tion Flowchart,
which is arranged
in the correct fault
locating
sequence.
3.06
The following
precautions
must be observed
when handling
PCBs:
DO
NOT:
l
Drop a PCB.
l
Stack one PCB on top of another.
l
Handle
a PCB without
discharging
any static
electricity
from your person
by touching
the
grounded
cabinet.
0 Touch
PCB contacts
with your fingers.
IMPORTANT!
If the fault is not cleared
by substituting
a
PCB, the original
PCB must
be reinstalled
in the cabinet
before
trying
another
PCB.
4 DEFECTIVE
APPARATUS
RETURNS
4.01 When adefective
system apparatus
is shipped
for repair,
the apparatus
must
be packed
in a
suitable
container
(the original box is highly recom-
mended),
as follows:
c) Plastic bags for electronic
telephones,
KSU,
etc.
.
4.02
NEVER
WRITE
ON THE APPARATUS
IT-
SELF!
Describe
the nature
of the defect
on an
information
tag. Attach the tag to the front of the unit
with string (not wire) so the tag can remain attached
during the testing and repair process.
Return tags
are available
from Toshiba
America
Information
Systems,
Inc., TSD Division.
4.03
If different
and/or additional
faults are created
in the system by substituting
a PCB, tag and return
the substitute
PCB as a defective
unit.
5 FAULT IDENTIFICATION
and
ELIMINATION
PROCEDURES
5.01
The PCTU PCB may contain a "soft" fault due
to static electricity.
If it is found defective
during the
fault finding procedures,
attempt to clear a soft fault
prior to returning
the PCTU
PCB for repair.
The
correct procedure
for this is to reinstall the PCTU,
perform
the initialization
procedure,
and then re-
program
the system
as necessary
to test for the
fault.
If the fault returns after these procedures
are
performed,
tag the defective
PCTU and return it for
repair.
6 POWER SUPPLY
a) Paper container
for the PCTU PCB.
b) Anti-static
containers
for all other PCBs.
6.01
If a DC power
fault is detected,
all PCBs
should
be disconnected
from the backplane
con-
nectars to eliminate
them as the cause of the power
CABLE
FROM REAR
OF POWER
SUPPLY
wz
g$gi;g
FG
-24V2
-5V
-24Vl
+5V
DG
CONNECTOR
BACKPLANE
FG
6
-24V3
5
+5VI
4
-5Vl
3
DG
2
DG
1
-24Vl
TBl
-24V2
TB2
Pl
P4
DK 56196
-24V4
TB3
DK 96
FG
-24V5
+5V2
-5V2
DG
DG
i-l
Check between
pins 1 and 2 (DG) and the desired voltage.
OBSERVE
THE CORRECT
POLARITY..
FIGURE P-BACKPLANE CONNECTORS Pl (DK24), PI & P4 (DK56/96)
-2-