PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS
SECTION 200-096-302
FEBRUARY1991
PROGRAM17
TIELlNEPAGE/HANDSFREEANSWERBACK
I,-,In~p-j-~~p@&T-j-~-p-j
/
Select = TIE Line
2
Key/LED
01 to enable
Enter the number of the
the Page/Handsfree
Answerback
CO line designated
as a
Feature on the TIE line defined.
TIE line (01 - 36).
See Note 4.
See Notes 3 and 6.
I
-~~
1
me
ine)
36
Keym
LED Lit
X=ON
I
PEMU 1
I
I
I
PCB
2
I
PEMU 2
PCB
Slot No.
NOTES:
1. For more information,
see the instructions
preceding
the record sheets.
2. System page access to external TIE line callers and handsfree
answerback
to stations receiving
TIE line calls can be allowed
with this program.
3. Shadedareas
of the table are for configuration
purposes.
Refer to Program
03 to find the PEMU PCB slot numbers.
Program
03 must be completed
prior to this program.
4. Be sure to specify both digits of the CO line assigned
as a TIE line. If the 0 before a single digit (01 - 09) is left out, the LCD
displays what is entered, but key LED 01 cannot be programmed.
5, All 20 key LEDs light if pressed,
but only key LED 0 1 has a programming
function.
6. Initialized data does not assign Page/Handsfree
Answerback
to any TIE line. LED 01 stays off for all CO lines.
7. A range of TIE lines may be programmed
by entering
/
Low TIE (CO)
High TIE (CO)
line in range
line in range
8. Maximum
PEMU PCBs allowed because of power supply limits: DK24 = 1 PEMU, DK56 = 2 PEMUs, DK96 = 3 PEMUs.
9. If PEMU is installed with PCTUS PCB, only 16 station ports are available.
IO.
I
When a PEMU is installed, it is automatically
assigned to the next consecutive
CO line andstation
p&s:
if the system is
quipped
with a PCTU (1,2, or 3) the PEMU assumes four CO lines and four station ports; with a PCTUS it assumes four CC lines and
eight station ports.
2-60