REMOTEADMlN&MAlNTPROCEDURES
SECTION 200-096-600
FEBRUARY1991
TABLERM-AK
PROGRAM47
TOLLRESTRICTIONEXCEPTION OFFICECODESASSIGNEDBYAREACODE
.
iTEP
ACTION
DISPLAY/PRINTOUT
1
Enter Program
Mode
>MODE PROG
At the >MODE prompt, enter 1 0 m 1
q
P
2
Enter Program
Number
47
P 47
Pressm
.
P47
3
Enter exception table (1 - 8) and press 0 .
P47 Y 1 AREA CODE NNN
4
Refer to the System Record Sheet and enter the required area
P47 Y 1 AREA CODE NNN 714
code and press
q
.
P47
Example:
AC 714, enter 610 1
q
.
5a
To Add Exception
Office Codes to Table
l
Enter exception table (1 - 8) and press B
P47 01
l
Enter exception codes 000
or 000
1 ~~~
.
Except
l
Press m
to add more codes.
l
Press m
(9
to store codes.
Except
000
5b
To Delete Exception
Office Codes from Table
l
Enter exception table (1 - 8) and press 1
P47 01
l
Enter exception codes ~~~
or ~~~
1 000
.
Delete
l
Press m
to delete more codes.
l
Press m
q
to store codes.
Delete
000
5c
To Display Exception
Office Codes in Table
l
Enter exception table (1 - 8) and press 1 m
.
P47 ng
l
Press m
to display more codes.
Except
no0
l
Press
q
to exit display.
6
To Exit Program/Store
Data: 1 1
q
P47 Y 2
Exceptn[70
P47 # #
P
-38-