to a hunting
sequence,
starting
with the Iow-
est port hunting
to the next highest port, etc.
The last hunt should be to an attendant.
l
Program
35: LEDs 01 and 02 must be ON
for stations
to receive the message
indica-
tion (MW LED flashing)
from a VM device.
l
Program
36: Set fixed call forward
to VM/
AA port per customer
requirements.
l
Program
37: Set the timer for the VM/AA
ports to 22 seconds
minimum
to allow call
forward
no answer to work on VM transferred
calls.
l
Program
39: Set the MW/FL,
CFF,
RDL
and
SDS
buttons
on the electronic
tele-
phones
that will be used to communicate
with the VM/AA device.
l
Programs 81
N 89: Verify that the ringing
assignments
to the VM/AA devices
are set
per customer
requirements.
l
Programs
16,40,41,45
N 48 and 50 N 56:
Verify that outgoing
CO line access
is al-
lowed on VM ports to allow the VM/AA beeper
notification
feature
to operate.
9.25 Voice Mail System Installation.
Install the
voice mail messaging
system
in accordance
with
the following
steps:
1) Ensure
that the PSTU or PESU PCB is in-
stalled in the system per Section 200-096-206.
2) Connect
the voice mail messaging
system to
the selected
PSTU or PESU standard
tele-
phone port (refer to Wiring Diagrams,
Section
200-096-290,
for PSTU
and PESU
wiring/
interconnecting
details).
3) Program
the system
for the required
voice
mail messaging
features
(refer to Paragraphs
9.13
and 9.22).
4) Ensure that a CRCU
(-4 or -8) is installed
on
the PCTU or PCTUSl
PCB, and verify that the
PCTU code in
Program 03
is for CRCU
op-
eration
as required.
5) Perform
additional
voice mail messaging
sys-
tem programming
as applicable
(refer to cus-
tomer-supplied
installation/programming
manuals).
INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY 1991
NOTE:
Some voice mail devices may ring tcip when
called; in
this
case, set the ring voltage jumper
to L (low position) on the PEW or PSTUZ
PCB connected to the voice mail device.
10 ALARM SENSOR INSTALLATION
10.00
The PIOU or PIOUS PCB provides
a circuit
that can be set to detect
a relay open
or closed
condition
from a facility alarm system.
When
the
sensor
is activated,
all electronic
telephones
will
sound
an alarm signal.
The electronic
telephone
alarm signal can be reset by any electronic
tele-
phone with an alarm reset button (see
Program 39).
10.01 Alarm Sensor Options.
Jumper
plug
PI2
on the PIOU is used to set the alarm
sensor
to
detect an open or closed condition
from the facility
alarm system.
Set
PI2
as follows
(refer to Figure
8-23) :
l
To detect a closed condition,
set
PI 2
to the N.O.
position.
l
To detect an open condition,
set
PI 2
to the NC.
position.
10.02
Jumper
W3
on the PIOUS is used to set the
alarm sensor to detect an open or closed condition
from
the facility
alarm
system.
Solder
the
W3
jumper
wire as follows (refer to Figure 8-22):
l
To detect
a closed condition,
solder W3 to the
normal open position.
l
To detect
an open condition,
solder W3 to the
normal closed position.
10.03 Alarm Sensor Wiring.
Refer
to Figure
8-23, and connect
the facility alarm system
relay
contacts
to the PIOU/PIOUS
PCB.
8-17