INSTALLATION-SYSTEM DESCRIPTION
SECTION 200-096-202
FEBRUARY 1991
IMPORTANT NOTES:
1. Local ordinances may dictate battery
type and installation details.
2. The reserve power batteries must be
installed while commercial AC power
is applied to the system to allow the
power supply reserve relay to operate.
If batteries are connected after AC
power is lost, the batteries WILL NOT
power the system and the system W/L L
NOT operate.
4.20 Battery Charger
4.21
To allow full normal system operation
during
a power
failure,
the power
supply
has a built-in,
current limiting battery charger that maintains
cus-
tomer-supplied
batteries.
Electrical
characteris-
tics of the battery
charger
include:
l
Nominal
float voltage:
2.275 volts/cell
l
Charge
current:
0.7 amps maximum
l
Battery discharge
cut-off voltage:
20.5 *O.!?V
5 POWER FAILURE/EMERGENCY
TRANSFER
UNIT
5.00
The Power Failure/EmergencyTransfer
Unit
(DPFT) provides
an optional
means
of ensuring
uninterrupted
telephone
operation
in the event of
a power failure. The DPFT (Figure 2-8) automati-
cally connects
selected
CO lines to standard
tele-
phone
lines in the event of a power failure, while
CO LINE
TEL LINE
POWER
FAILURE
TRANSFER
FIGURE 2-8-POWER FAILURE
TRANSFER UNIT (DPFT)
permitting
normal operation
when the system
is in
service.
5.01
The DPFT is a self-contained
module
that
mounts
externally
to the system's
KSU, typically
near the MDF. Connections
to the CO lines, stan-
dard telephones
and the cabinet
are made with
two50-pinamphenol-typeconnectorson
theDPFT.
5.02 The DPFT consists
of eight normally
open
relays, connecting
the telephones
to PSTU (Stan-
dard Telephone
Interface
Unit) PCB circuits and
the CO lines to PCOU (CO Line Unit) PCB circuits
(Figure
2-9). If a power failure occurs, the relays
close, connecting
the telephones
directly
to the
CO lines. Calls can then be placed
from the se-
lected
standard
telephones,
over the CO lines,
completely
bypassing
the system.
5.03
When
the DPFT
is reset after a transfer,
existing PFT conversations
are protected.
Individ-
ual circuits are restored
only when they become
idle.
6 PRINTED CIRCUIT BOARD
DESCRIPTIONS
6.00
Twelve types of PCBs are available for use in
STRATA
DK systems.
A maximum
of seven PCBs
can be installed
in DK24, nine in DK56, and fifteen
in DK96.
6.01
With the exception
of the PCTU and PCTUSl
PCBs,
PCB size and connector
provisions
are
standardized.
All PCBs,
including
the
PCTU/
PCTUSl,
measure
7.5 x 5.5 in (190 x 140 mm).
The PCBs connect
to the KSU's backplane
with
identical
40-pin
male connectors.
Except for the
PCTU/PCTUSl
PCBs, the connectors
are posi-
tioned
in the same location
on each board type.
6.02
PCB external
connections
are made to the
Main Distribution
Frame (MDF) using the following
industry-standard
connectors:
l
25-pair Amphenol Female:
Twenty-five-pair
amphenol
connectors
connect
electronic
tele-
phones,
standard
telephones
and most periph-
erals.
I
l
Modular:
Modular
jacks connect
CO lines, E &
M TIE lines, the Station
Message
Detail
Re-
2-6