INSTALLATION-SITE REQUIREMENTS
SECTION 200-096-203
FEBRUARY 1991
4 CABLE LENGTHS/NETWORK
REQUIREMENTS
4.00
Table
3-A lists system
loop requirements.
Table 3-B lists system
network
requirements.
The
KSU must be located to allow compliance
with the
specified
requirements.
5 GROUNDING
REQUIREMENTS
5.00 The system requires
a solid earth ground for
proper operation.
Failure to provide such a ground
may lead to confusing
trouble
symptoms
and, in
extreme
cases, system
failure.
The ground
con-
nection is provided
by the "third wire ground"
from
the commercial
power outlet.
NOTE:
The ground
must be dedicated.
5.01
At most installations
in the continental
United
States,
the ground
provided
by the "third wire
ground"
at the commercial
power outlet is satisfac-
tory for system requirements.
However,
in a small
percentage
of installations,
this ground
may be
installed
incorrectly.
Before
installing
a system,
test the third wire ground
for continuity
by either
measuring
the resistance
between
the third prong
terminal
(earth
ground)
and a metal
cold water
pipe (maximum:
5 ohms),
or by using a commer-
cially available
earth ground
indicator.
5.02
If neither
procedure
is possible,
perform
the
earth ground
test procedure
in Paragraph
5.10.
I
NOTE:
See Paragraph
7 for more
grounding
re-
quiremen
ts.
5.10 Earth Ground Test
WARNING!
Hazardous voltages that may cause death
or injury are exposed during the folio wing
test. Use great care when working with AC
power line voltage.
1) Obtain
a suitable
voltmeter,
and set it for a
possible
reading
of up to 250 VAC.
2) Connect
the meter
probes
between
the two
main AC voltage
terminals
(white
and black
wires) on the wall outlet. The reading
obtained
should be between
100 - 120 VAC.
3) Move
one of the meter
probes
to the third
terminal
(green wire ground).
Either the same
reading
or a reading
of zero volts should
be
obtained.
4) If the reading
is zero volts, leave one probe on
the ground
terminal
and move the other probe
to the second voltage
terminal.
CAUTION!
If a reading of zero volts is obtained on
both voltage terminals (white wire to green
wire, black wire to green wire), the out/et is
not properly grounded. Omit steps 5 and
6, and proceed directly to step 7.
5) If a reading
of zero volts on one terminal,
and a
reading of 100 - 120 VAC on the other terminal
is obtained,
remove
both probes
from the out-
let.
6) Set the meter to the "OHMS/Rx1
" scale. Place
one probe on the ground terminal,
and the other
probe on the terminal
that produced
a reading
of zero volts. The reading should be less than 1
ohm.
CAUTION!
If the reading is more than one ohm, then
the outlet is not adequately grounded.
7) If the above tests show the outlet is not properly
grounded,
the condition
should
be corrected
(per Article 250 of the National
Electrical Code)
by a qualified
electrician
before
the system
is
connected.
3-2