Toshiba STRATA DK24 Manual page 627

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

REMOTEADMlN&MAlNTPROCEDURES
SECTlON200-096-600
FEBRUARY1991
TABLERM-K
PROGRAM03
FLEXIBLEPCBSLOTASSIGNMENTS
;TEP
ACTION
DISPLAY/PRINTOUT
1
Enter the Program
Mode
>MODE PROG
At the >MODE prompt, enter w 1 m 1 (9.
P
2
Enter Program
Number 03
P 03
Press
q
.
PO3
3
Enter the Slot Number
PO3
Refer to the System Record Sheet and enter the desired
PO3 00 91
slot number.
Example:
Slot number 00, enter 1 1.
4
Enter the PCB Code Number
PO3
Refer to the System Record Sheet and enter the desired
PO3 00 91 92
PCB code number.
Example:
PCB code 92, enter 1 1 .
5
To Exit Program/Store
Data
PO3
A) To store data, press
q
.
PO3 00 91 92
B) Continue returning to step 3 until all
Program 03
PO3
##
data is entered.
P
C) To exit this program, press 1 1, press
q
6
Turn system power "OFF" for 5 seconds and then turn
Remote
maintenance
is disconnected.
power "ON" to store data in working memory (see Notes).
IMPORTANT
NOTES:
1. This program
must be completed
with on-site
assistance
(after installing
PCBs) because
the
system
must be powered
down momentarily
after PCB code entry.
2. Even though PCB codes display as being changed,
they are not entered
into working memory
until
the system
DC power
is cycled OFF and ON.
3, If PCB codes are not entered
into working
memory
by cycling DC power,
PCB options
will not
function.
4.
Only
Program
03 requires
the system power
to be turned OFF and ON to store data into working
memory.
-19-