Hesc-65 - Toshiba STRATA DK24 Manual

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY1991
telephones
and
1 OOO-series
digital
telephones
equipped
with HHEU PCBs (refer to Section 200-
096-207).
The HESB automatically
turns off once
the ringing
call or voice first has been
manually
answered
from the electronic
or digital telephone.
This turn-off feature
prevents
audio feedback
prob-
lems.
5.02 Amplified
Speaker
Option.
The Amplified
Speaker
option allows the HESB to be configured
as a paging speaker.
The HESB is connected
to the
PIOU, PIOUS,
or PEPU 600-ohm
page output
to
provide
an amplified
external
speaker.
5.03 Talkback
Amplified
Speaker
Option.
The
Talkback Amplified
Speaker option allows a talkback
speaker to be provided
in areas where a telephone
is not needed,
such as in conjunction
with a door
phone. In this configuration,
the HESB is connected
to the PIOU, PIOUS, or PEPU 6OOQ (duplex) output
and is used as the amplifier and speaker.
The door
phone unit (MDFB) is connected
to the HESB, and
serves as a microphone
to provide talkback opera-
tion (the MDFB pushbutton
is inoperative,
and the
unit serves only as a microphone
for talkback).
NOTE:
The PIOU, PIOUS, and PEPU 600 Q (duplex)
page output is compatible
with most commer-
cially available
talkback
amplifiers.
5.10
System
Hardware
Requirements
5.11
System
hardware
requirements
vary de-
pending
on the HESB option selected.
Refer to the
following
installation
procedures
for the system
hardware
requirements
for each option.
5.20
HESB Option
Installation
5.21
Loud
Ringing
Bell Installation.
Install the
HESB Loud Ringing
Bell option in accordance
with
the following
steps (refer to Figure 8-l 1 for elec-
tronic or 8-l 1 A for digital telephones).
1) Connect
a jumper
between
terminals
6 and 7
on the HESB TBI terminal
block.
2) Connect
a jumper
between
terminals
5 and 8
on the HESB TBI terminal
block.
3) Connect
a jumper
between
terminals
4 and 5
on the HESB TB2 terminal
block.
NOTES:
1.
2.
4)
5)
6)
7)
8)
9)
t
t
t
t
HESB connections
made in steps 4 N 7
may be accomplished
using
the HESB
VOICE modular
jack instead
of the TBI
terminal
block.
Install an HHEU PCB and HESC-65
cable
in the 6500-series
electronic
telephone
per
Section
200-096-207
before
pro-
ceeding
with steps 4 and 5.
Connect terminal
1 of the HESB TBI terminal
Ilock to the red (+) wire of the HESC-65
cable
Jsing a modular
block per Figure 8-l 1.
Connect terminal
2 of the HESB TBI terminal
slack to the green
(-) wire of the HESC-65
:able using a modular
block per Figure 8-l 1.
Connect terminal
3 of the HESB TBI terminal
Ilock to pin 3 of the electronic
telephone's
nodular
block (VOICE-TIP).
Connect terminal
4 of the HESB TBI terminal
Yock to pin 4 of the electronic
telephone's
nodular
block (VOICE-RING).
Connect the HACU-120
power supply's +12V
ead to terminal
1 of the HESB TB2 terminal
Ilock, and connect
the power supply's OV lead
0 terminal
2.
Plug the provided
power cord into the power
supply and to a 117VAC,
60Hz power source.
NOTE:
See Figure
8-24
for HESB
wall mounting
instructions.
5.22
Loud Ringing
Bell Test. Test the Loud Ring-
ing Bell installation
in accordance
with the following
steps:
1)
2)
3)
Make a CO or station call to the station config-
ured for the loud ringing bell.
l
Ringing
will be heard over the HESB.
Adjust the HESBvolume
control to the desired
level.
If ringing is heard at the station,
but not over
the HESB, perform
the following
check while
the station is ringing:
a) Using a suitable voltmeter,
measure
volt-
age across terminals
1 (+) and 2 (-) of the
HESB TBI terminal
block.
l
Voltage
indication
should
be 4.5 N
5.0 VDC.
8-8