INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY1991
nance
modem
to the PIOU
or PIOUS
PCB is
accomplished
with a standard
3-pair modular
cord
and a PPTC adaptor
connected
to the PIOU or
PIOUS TTY jack (refer to Figure 8-21).
NOTE:
If the IMDUmodem
is used, the PPTC adapter
or modular
cord is not required.
8.20 Local Maintenance Terminal Installation
8.21
Install the ASCII terminal
in accordance
with
the following
steps (refer to Figure 8-21):
1) Connect
the 3-pair modular
cable (or 24 AWG
twisted
pairs) and the PPTC adaptor
from the
PIOU or PIOUS TTY port to the remote main-
tenance
terminal
DB25 connector.
2) Set the PIOU or PIOUS SW2 switch to match
the modem
or terminal
baud rate:
l
Push in for 300 bps (baud rate indicator
CD4 is lighted);
let out (by pushing
again)
for 1200 bps (CD4 is not lighted).
3) Set the PIOU or PIOUS SW3switch
to
theTTY
position.
4) Set the P13 jumper
plug on the PIOU to the
BELL
configuration,
or cut the W4 jumper
on
the PIOUS (also for
BELL
configuration).
NOTE:
The PI3
(PIOU)
and
W4 (PIOUS)
CCITT
configurations
are not normally
used in the
USA.
5) Programming
and system
testing,
via the
maintenance
terminal,
is described
in the
Remote
Maintenance
Procedures,
Section
200-096-400.
NOTE:
If the electronic
telephone
connected
to pot?
05 is in the program
mode, programming
from
the maintenance
terminal
is not allowed.
8.30 Remote Maintenance Option Installation
8.31 IMDU Maintenance
Modem.
The
IMDU
modem
mounts
on the PIOU or PIOUS PCB and
provides
300 or 1200 bps, full-duplex
communica-
tion for remote
maintenance.
If the IMDU is em-
ployed,
a dedicated
CO line, PSTU,
oi PESU
connection
is not required.
Connection
of the re-
mote maintenance
terminal
is through
existing sys-
tem CO lines via intercom
number
19. Refer to the
PIOU or PIOUS portion of Section 200-096-206
for
details on hardware
installation
and programming
requirements.
Remote
Maintenance
Procedures,
Section
200-096-400,
provides
more information
about using the IMDU for remote
maintenance.
.:
:
8.32 External Maintenance Modem Installation.
Install the external
modem
in accordance
with the
following
steps (refer to Figure 8-21):
NOTE:
The Toshiba PPTC IX-232
modular-to-D925
adaptor
is factory-configured
for ASCII termi-
nal connection.
Pins 2 and 3 of the adaptor
must be reversed
for external modem connec-
tion.
1)
2)
3)
4)
Connect
the modular
cord from the PIOU or
PIOUS
TTY port to the PPTC adapter
and
then to the external
maintenance
modem
RS-
232 25pin
connector.
Connect
the external
maintenance
modem
line-side to a dedicated
CO line (tip and ring)
or to a dedicated
PSTU or PESU standard
telephone
port (tip and ring). Refer to Wiring
Diagrams,
Section
200-096-209,
for wiring/
interconnecting
details.
Set the PIOU or PIOUS SW2 switch to match
the modem
or terminal
baud rate:
l
Push in for 300 bps (baud rate indicator
CD4/LED
is lighted);
let out for 1200 bps
(CD4 is not lighted).
Set the PIOU or PIOUS SW3switch
to the TTY
position.
NOTE:
The PIOU or PIOUS SW3 switch is set to the
MODEM
position
for IMDU operation
only.
5) Set the
PI3
jumper
plug on the PIOU to the
BELL
configuration,
or cut the W4 jumper
on
the PIOUS (also for
BELL
configuration).
-.,
. . :;'
8-14