6 SITE CONSIDERATIONS (continued)
6.00 The following
precautions
should be adhered
to when installing
telephone
wiring:
GROUND
1;
THIRD WIRE GRO;ND
\
TO AC POWER
CORD
WARNING!
1. Never install the telephone wiring dur-
ing a lightning storm.
2. Never install the telephone jacks in wet
locations unless the jack is specifically
designed for wet locations.
3. Never touch uninsulated
telephone
wires or terminals unless the telephone
line has been disconnected at the net-
work interface.
4. Use caution when installing or modify-
ing telephone lines.
7 GROUNDING REQUIREMENTS (continued)
7.00
In addition
to the grounding
provisions
in
Paragraph
5, the following
grounding
provisions
must be adhered
to (Figure 3-3):
1) Redundant
and
independent
equipment
grounding
conductors
are to be installed
be-
tween the product and the wiring system ground.
2) One of the equipment
grounding
conductors
(ground
1) shall be an insulated
grounding
conductor
that is not smaller
in size and is
equivalent
in insulation
material
and thickness
to the grounded
and ungrounded
branch-circuit
supply conductors,
except that it is green with
or without
one or more
yellow
stripes.
The
grounding
conductor
is to be installed as part of
the circuit that supplies that system and is to be
connected
to ground
at the service equipment.
3) The other conductor
(ground
2) shall comply
with the general
rules for grounding
contained
in Article 250 of the National
Electrical
Code,
NFPA 70, but shall not depend
on the cord and
plug of the product.
7.10 Second Ground Test
WARNING!
Hazardous voltages that may cause death
INSTALLATION-SITE REQUIREMENTS
SECTION 200-096-203
FEBRUARY 1991
THIRD WIRE
AC GROUND
\
\
DKSU
\ II
A+
t A
ELECTRICAL
SYSTEM
GROUND
POWER
'
SUPPLY
BUILDING
GROUND
OR
COLD WATER
PIPE
*f
INSULATED
GROUND
WIRE
FRAME GROUND
SCREW ON DKSU
GROUND
2;
PER GENERAL
RULES
OF ARTICLE
250 OF
THE NATIONAL
ELECTRICAL
CODE, NFPA70
FIGURE 3-3 KSU GROUNDING DIAGRAM
or injury may be exposed during the
following
test. Use great care when
working with AC power line voltage.
1) Refer to Figure 3-3.
2) Disconnect
the AC plug of the system to make
sure
that
the
two
earth
ground
paths
are
separated.
3) With
a suitable
volt/ohm
meter,
perform
a
reading
between
A and
B. Verify
that
the
readings
do not exceed the figures listed below.
If they do, the condition
must be corrected
by a
qualified
electrician
before the system
is con-
nected.
A to B: 1 volt maximum
then
A to B: 1 ohm maximum
3-5