HP 1660E Series Service Manual page 53

Logic analyzers
Table of Contents

Advertisement

Testing Performance
To test the single-clock, single-edge, state acquisition (logic analyzer)
Connect the logic analyzer
1 Using the 6-by-2 test connectors, connect the first combination of logic analyzer
clock and data channels listed in one of the following tables to the pulse generator.
If
you are testing an HP 1660ElESIEP or HP 1661EIIESIEP, you
will
repeat this test for the
second combination.
2 Using SMA cables, connect the oscilloscope to the pulse generator channell
Output, channel 2 Output, and Trigger Output.
Connectthe
HP
1660E/ESjEP or
HP
1661 E/ESjEP Logic Analyzer to the Pulse Generator
Testing
Combinations
2
Cunnectta
HP B133A
Channel 2 Output
Pod 1, channel 3
Pod 3, channel 3
Pod 5, channel 3
Pod 7, channel 3
Pod 1, channel 11
Pod 3, channel 11
Pod 5, channel 11
Pod 7, channel 11
Connect to
HP B133A Channel
2 Output
Pod 2, channel 3
Pod 4, channel 3
Pod 6, channel 3
Pod B, channel 3
Pod 2, channel 11
Pod 4, channel 11
Pod 6, channel 11
Pod B, channel 11
Conneetto
HP Bl33A Channel
1 Output
J-clock
J-clock
3-27